Software packages for set-up, transfer and data analysis: 
SquirrelView Plus

 

Provides full data analysis, on-line graphing, meter to Excel and export to Excel 

SQA200 

SquirrelView Plus Multi-User License

  

Unlimited use of SquirrelView within a single organisation. 

SQA300 

Calibration Certificates for Squirrel 2010 series (all ranges) 

Note: Test and Calibration Certificates from Grant Instruments are traceable to 
National Standards 
SQ2010 

CAL2010 

Weatherproof box 

Robust plastic weatherproof box 

PEL4 

Power supplies 

100-240V AC 50/60Hz supplied with 3-single fit mains plugs for UK, Euro, and US 

MPU 12V 

As MPU 12V but supplied with 1m flying lead   

MPU 12VFL 

Rechargeable battery (12V, 6Ah) 

SQ20RB12-6 

Rechargeable battery (12V, 15Ah) 

SQ20RB12-15 

Digital I/O interface connector   
25 way D connector type sub miniature solder connection with cover for digital 
inputs, alarm and pulse inputs   

SB102 

Current Shunts

 

Pack of 4 precision resistors for 4-20mA inputs 

CS202 

Cables for connecting data loggers to computers/modems.

 

Squirrel to PC serial port  

LC71 

Squirrel to PC USB port  

LC77 

Squirrel to modem 

LC73 

12V DC power lead

 

2.1mm DC connector and fused with 1.8M lead 

LC76 

Terminal blocks 

Plug-in terminal blocks with cable restraint 
3-way   

14174 

6-way   

18097 

Temperature and Humidity probes 

Grant offers a range of temperature and humidity probes suitable for use with its data loggers and 
other compatible measurement systems. Bespoke or specialist probes are also available. Please  
enquire if you have specialist probe needs. 

Содержание Squirrel SQ2010 SERIES

Страница 1: ...Getting Started 2010 SERIES Squirrel Data Logger www omniinstruments co uk...

Страница 2: ...Start Example 5 5 Download Process Explained 9 6 Menu and Navigation 10 7 Connections 14 8 Accessories 16 9 Specifications 18 10 Declaration of Conformity Inside rear cover After reading this guide p...

Страница 3: ...2010 Logger C CD containing software SQA100 D Getting Started manual this booklet E USB Cable LC77 F Batteries 2 x C G Current shunt resistors for 4 to 20mA inputs 10R x 4 CS202 H Connectors 6 way x 2...

Страница 4: ...dition Battery indicator When logging please ensure that the batteries in the unit have sufficient capacity to complete the logging task This can be checked via the battery indicator located in the to...

Страница 5: ...ruments SQ20XX USB device drivers Win 7 Vista USB Device Drivers are automatically installed and no further action is required Important Please ensure the software is installed before connecting the S...

Страница 6: ...lView or select it from your start menu When the SquirrelView Assistant is loaded ensure the correct logger type and communication method is selected Logger type can be viewed from the SquirrelView as...

Страница 7: ...ll down the Sensor Type column to Ref Junction 1 This is the input you will be reading in this example The Job Description can be used to describe your setup In the SquirrelView Assistant click Logger...

Страница 8: ...stant Click if you wish to meter the input in Real Time Click on Logger Control icon to pause or stop the logging process In the Logger Control window you can view relevant information on the state of...

Страница 9: ...name is shown on the right this shows the date and start time In this example you will download and view the Data in the Analysis window Start by selecting the Data File and Graph Data action then cli...

Страница 10: ...process can be performed in one of three ways within SquirrelView from SquirrelView assistant Analysis Export Data File automatically when using the download Data button from SquirrelView or from the...

Страница 11: ...e detail To use the 2010 control panel press the opening display will be shown see right The display timeout is preset to 10 seconds however this can be changed by selecting the Configuration tab with...

Страница 12: ...larm outputs from here 6 2 4 Setup This contains menus for setting the Language Time Date basic Channel Setup storing and recalling setups and Delayed start See 6 3 for more details on basic setup 6 2...

Страница 13: ...etup you can clear all channels add edit a channel view channel details or delete a channel Select Add Edit Channel 6 3 3 Adding a New Channel The Add Edit Channel menu shows channels currently set as...

Страница 14: ...in the case of a more complex setup from SquirrelView To avoid problems with wiring configuration sensor types are not editable once set but their range and sensor power requirements can be Delete a...

Страница 15: ...wiring diagram to attach the required sensor If you would like to print the diagrams in more detail or view at a later stage select File Print from Logger Setup Analogue Inputs The example below show...

Страница 16: ...2 Event State Input 2 3 Event State Input 3 4 Event State Input 4 5 Event State Input 5 6 Event State Input 6 7 Event State Input 7 8 Event State Input 8 9 Ground 10 Alarm Output A 11 Alarm Output B...

Страница 17: ...our local supplier for more details RS232 to Ethernet Converter consisting of adaptor box and modem setup Part No Cable Ethernet configuration software is suitable for Windows XP only SQ20A801 GSM Mod...

Страница 18: ...lead MPU 12VFL Rechargeable battery 12V 6Ah SQ20RB12 6 Rechargeable battery 12V 15Ah SQ20RB12 15 Digital I O interface connector 25 way D connector type sub miniature solder connection with cover for...

Страница 19: ...24bit Sampling rate Up to 10 readings per second ALARM OUTPUTS 2 x open drain FET 18V 0 1A Max SENSOR POWER SUPPLY Regulated 5 VDC 50mA or supply voltage 100mA TIME AND DATE In built clock in 3 format...

Страница 20: ...overwrite DISPLAY AND KEYPAD 128 x 64 pixel LCD OPERATING ENVIRONMENT 30 C to 65 C Using Supplied Batteries 20 C to 50 C Windows is a registered trademark of Microsoft Corporation in the United States...

Страница 21: ...SQ2010 28507 Version 6 Page 20 EN Personal Notes...

Страница 22: ...d Standards EN 61326 1 2006 Electrical Equipment for measurement control and laboratory use EMC requirements Part 1 General requirements Emissions tested for Class B equipment Immunity tested to Table...

Страница 23: ...or Pricing and any further information please contact Omni Instruments Ltd Suite E Ground Floor East Kingsway Business Centre Mid Craigie Trading Estate Mid Craigie Road Dundee DD4 7RH Email info omni...

Отзывы: