Page 5

 2 USING 

YOUR

 BOILER

2.1 

LIGHTING YOUR BOILER

The lighting procedure is:

1. Ensure 

that:

a)  There is su

  cient fuel, of the correct type, in the 

supply tank and that all fuel supply valves are open.

b)  The water supply is on.
c)  The electricity supply to the boiler is OFF.
d)  The boiler On/O

  switch is set to OFF.

e)  The room thermostat (if 

fi

 tted) is at the desired setting.

f) 

The boiler thermostat is set to the required setting.

2.  Switch the electricity supply to the boiler ON.

3.  Set the boiler On/O

  switch to ON.

If 

fi

 tted, set the programmer to ON (either central heating 

(CH) or hot water (HW)).

4.  The boiler will now light automatically.

5.  If a programmer is 

fi

 tted, refer to the instructions supplied 

with the programmer and set the CH and HW functions to 

TIMED.

The boiler will now operate during the ‘on’ periods set on the 

programmer.

2.2 IF 

YOUR BOILER FAILS TO LIGHT

Make the following checks:

1.  Check that the boiler On/O

  switch is set to ON.

2.  Check that the programmer (if 

fi

 tted) is working and is set to 

ON (CH or HW).

3.  Check that all thermostats are set to the desired setting and 

are calling for heat.

4.  Check if the burner ‘Lock-Out’ reset button on the burner 

body (refer to Figure 1-1 for location) is lit.

If it is, press it to start the burner.

If the burner fails to light and goes to ‘Lock-Out’ again, check 

that you have su

  cient fuel in the storage tank and that the 

fuel supply valve is open.

5.  Check that the 

fi

 re valve in the oil supply line has not tripped.

6.  Ensure that a fuse has not blown or that the electricity supply 

has not failed.

7.  Check to see if the overheat thermostat has operated (see 

Section 2.5).

If the burner still fails to light after carrying out these checks then 

a fault exists or the fuel supply is low. If you have su

  cient fuel, 

switch o

  the electricity supply to the boiler and contact your 

service engineer.

2.3 

TURNING OFF YOUR BOILER

To turn o

  your boiler:

• 

For short periods-

Set the On/O

  switch to OFF.

To restart, simply set the switch to On.

• 

For long periods-

Set the On/O

  switch to OFF and switch o

  the electricity 

supply to the boiler. If required, the fuel supply valve may be 

closed and the water and electricity supplies turned o

  at the 

mains.
To restart, refer to Section 2.1 (Lighting your Boiler).

2.4 

ABOUT YOUR FUEL

Grant Euro

fl

 ame boilers only operate on Class C2 Kerosene to 

BS 2869:1998.
You should always quote this type of fuel when ordering from your 

supplier.
Do not wait until the fuel runs out before you order some more 

as sludge in the bottom of the tank may be drawn into the fuel 

lines. If it is possible, switch o

  the boiler when the new supply is 

delivered and leave the fuel to settle for an hour before restarting 

the boiler.

2.5 

BOILER CONTROLS

BOILER THERMOSTAT

This dial, located on the boiler control panel, allows the 

temperature of the water leaving the boiler to heat the radiators 

(and/or other heat emmiters if 

fi

 tted) and domestic hot water to be 

adjusted. 
Refer to Figure 1-1 for the location of the control panel within the 

boiler casing and Figure 2-1 for the details of the control panel.

! NOTE !

If you have a cylinder thermostat on your hot water 
cylinder, this will control the temperature of your domestic 
hot water. 
The boiler thermostat setting must be equal to or greater 
than the cylinder thermostat setting to enable the cylinder 
thermostat to control the domestic hot water system.

OVERHEAT THERMOSTAT

Your boiler is 

fi

 tted with a safety overheat thermostat which 

will automatically switch o

  the boiler in the case of a control 

malfunction causing overheating. 
If your boiler goes o

  and you try to light it but nothing happens 

and the ‘Lock-Out’ reset button on the burner is not lit, the 

overheat thermostat has probably operated. The boiler will not 

light until the overheat thermostat is reset. 
To reset the overheat thermostat, unscrew the small plastic cap 

marked “reset” (see Figure 2-1), press the button and replace the 

cap.
If this condition continually repeats, contact your service engineer.

Figure 2-1:

 Euro

fl

 ame Condensing Utility boiler control panel

Section 2: Using your Boiler

Содержание EFCON5090IND

Страница 1: ...IRL DOC 0023 Rev 02 00 October 2022 Grant Euroflame Condensing Internal Condensing Oil Boiler Range User Instructions ...

Страница 2: ...Flame boilers DOES NOT comply with ErP requirements or EU regulations and as a result Grant does not condone its use If your boiler uses Bio Kerosene B30K refer to the installation and servicing instructions NOTE This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been g...

Страница 3: ...2 If your boiler fails to light 5 2 3 Turning off your boiler 5 2 4 About your fuel 5 2 5 Boiler controls 5 2 6 Heating system controls 6 2 7 Electricity supply 6 3 CARING FOR YOUR BOILER 6 3 1 Checking sealed system pressure 6 3 2 How to fill or top up your sealed system 7 3 3 Expansion vessel 7 3 4 Ventilation 7 3 5 Flue terminal and condensate disposal 7 3 6 Frost protection 8 3 7 Failure of ele...

Страница 4: ...thin 30 days of its installation To register your boiler please ensure the completed boiler passport is returned to Grant or visit the Grant website www grant eu Your installer may have registered the boiler on your behalf and provided you with the relevant documentation If registered within 30 days your boiler will have a 5 year guarantee on the boiler shell and 1 year on the burner and other com...

Страница 5: ...to OFF To restart simply set the switch to On For long periods Set the On Off switch to OFF and switch off the electricity supply to the boiler If required the fuel supply valve may be closed and the water and electricity supplies turned off at the mains To restart refer to Section 2 1 Lighting your Boiler 2 4 ABOUT YOUR FUEL Grant Euroflame boilers only operate on Class C2 Kerosene to BS 2869 1998 Y...

Страница 6: ...the radiator As the correct operation of a TRV is based on it sensing the air temperature of the room it is fitted in take care not to cover the TRV head with curtains furniture etc Refer to the manufacturer s instructions supplied with any TRVs fitted to your heating system for further details 2 7 ELECTRICITY SUPPLY The boiler requires a 230 240 V AC 50 Hz supply It must be protected by a 5 Amp f...

Страница 7: ... person should always be undertaken 3 4 VENTILATION Unless your boiler is installed with a balanced flue system you will require ventilation openings in your property to provide your boiler with a fresh supply of air in order for it to fire Any ventilation openings in the property provided by the installer must not be obstructed You should periodically check that they are clear Do not attempt to b...

Страница 8: ...with the annual service details recorded as appropriate Seciton 3 Caring for your Boiler Section 4 After Sales Support 3 6 FROST PROTECTION Your installer may have fitted a frost thermostat If not and you are likely to be away for a short time leave the boiler on with the boiler thermostat set at a low setting If the boiler is not going to be used for longer periods of time the boiler and system s...

Страница 9: ...s Signature Service 4 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature Service 5 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature Service 6 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature Service 7 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature ...

Страница 10: ...ice 12 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature Service 13 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature Service 14 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature Service 15 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature Service 16 D...

Страница 11: ...Page 11 Notes NOTES ...

Страница 12: ...GRANT ENGINEERING IRELAND ULC Crinkle Birr Co Offaly R42 D788 Ireland Tel 353 0 57 91 20089 Email info grantengineering ie www grant eu ...

Отзывы: