2.2.1 

C1GR, C2GR 

 

The C1GR and C2GR are designed for use with the Grant ST Series baths.  The C2GR is only suitable for 
fitting in the 26, 28 and 38 litre baths. 

 

For fitting immersion coil in the ST series baths: 

1.  Remove bridge plate from ST bath. Remove the black 

rivets to separate the blanking plate. Retain the rivets 
for later 
 

2. 

Use the thumb screws provided to secure the “u” 
shaped bracket to the blanking plate as shown. 
 

3.   

Slide the cooling coil over the “u” shaped bracket and 

feed the cooling coil through the bridge plate. Check 
that the coil hose fits through the cut out. 
 

4.  Secure the blanking plate with the rivets. 

 

Ensure that the unit is located so that the ventilation grilles 
are not less than 100mm from any obstruction. 
 
The cooling coil may be immersed in liquids up to 100°C but 
the cooler should only be used to cool down the liquid, not to 
operate continuously above 40°C. 
 
Immersed material:   the cooling coil is nickel plated copper. 
 

2.2.1 

CC26R 

 

 The CC26R is designed for use with the Grant OLS26 shaking water baths. 
 
For fitting immersion coil into the OLS26 shaking water bath: 

 

1.  Remove shaking tray and trolley from the OLS26 

 

2.  Position the CC26R cooling unit next to the OLS26. Ensure that the ventilation grilles are more than 

100mm from any obstruction 
 

3.  Place the immersion coil in the base of the bath with 

the feed pipe at the rear. Hold in place with the 
retaining plate 
 

4.  Slide the 

locking plate onto the bath’s cam block 

housing and fasten with the 2 thumbscrews 
 

5.  Refit the shaking trolley and tray 

 

Grant recommends a 50% water and Ethylene glycol 
(antifreeze) solution. Please follow the instruction included 
with the OLS26 shaking water bath regarding filling the unit, 
setting operating temperature and shaking speed.  
 
The cooling coil may be immersed in liquids up to 100°C but 
the cooler should only be used to cool down the liquid, not to 
operate continuously above 40°C.  
 
Immersed material:   the cooling coil is nickel plated copper 

 

 

Содержание C1GR

Страница 1: ...Refrigerated immersion Coolers C1GR C2GR CC26R Operating Manual...

Страница 2: ...t Instruments Cambridge Ltd Shepreth Cambridgeshire SG8 6GB UK Tel 44 0 1763 260 811 E mail support grantinstruments com Representative in the European Union Grant Instruments Europe B V Strawinskylaa...

Страница 3: ...s 7 3 1 Operating condition 7 3 2 Electrical details 7 3 3 Performance and dimensions 7 4 Maintenance and service 6 4 1 General 8 4 2 Cleaning 8 4 2 1 General 8 4 2 2 Condenser cleaning 8 4 3 Routine...

Страница 4: ...ect only to an ac power mains outlet with a voltage corresponding to that on the serial number label This product must be connected to an earthed ac power mains outlet Before moving disconnect from th...

Страница 5: ...age trip Check that the voltage rating of the products given on the serial plate next to the power cable entry is correct for your supply Fit the mains cable appliance coupler into the IEC socket at t...

Страница 6: ...cool down the liquid not to operate continuously above 40 C Immersed material the cooling coil is nickel plated copper 2 2 1 CC26R The CC26R is designed for use with the Grant OLS26 shaking water bath...

Страница 7: ...ge fluctuations are not to exceed 10 of the nominal supply voltage C1GR Mains supply 220 240V 50Hz 115 127V 60Hz Power consumption 0 9 A 3 0A C2GR Mains supply 220 240V 50Hz 115 127V 60 Hz Power consu...

Страница 8: ...ed electrician and or Grant appointed representative on a regular basis to prevent the build up of foreign material within the equipment 4 3 Routine safety tests If routine tests are to be made we rec...

Страница 9: ...for THREE YEARS against faulty materials or workmanship Service repairs outside of the guarantee period by Grant Instruments carry a further one year guarantee 6 Service For service return for repair...

Страница 10: ...Agency this reference number is WEE GA0048TZ For other countries please contact your equipment supplier For General WEEE information please visit www b2bcompliance org uk 7 2 RoHS Directive All the pr...

Страница 11: ...C1GR C1GR US C2GR C2GR US CC26R CC26R US Operating manual Part No 34960 Page 11 www grantinstruments com Notes...

Страница 12: ...ents Cambridge Ltd Representative in the European Union Shepreth Grant Instruments Europe B V Cambridgeshire Strawinskylaan 411 SG8 6GB WTC Tower A 4th Floor UK 1077 XX AMSTERDAM THE NETHERLANDS Tel 4...

Отзывы: