Compressor Operating Instructions
61099050
5
3.
Performance specifications
3.1.
Intended use
The compressor is an oil lubricated air compressor. The ambient air is sucked in via the intake
filter and cleaned. The air drawn in is then compressed in the cylinder. The compressed air
flows into the pressure tank and is now available to supply the connected compressed air
tools. This compressor is designed exclusively for compressing air.
NO flammable gases and/or paint and dust mist may be sucked in with this compressor. It
may not be used in potentially explosive atmospheres as this may lead to serious or fatal
accidents with high material damage.
The suction of flammable gases etc. can lead to deflagration and explosions. This can
result in serious to fatal injuries and extensive damage to property!
The compressor has a finger guard and is thus protected against the penetration of medium-
sized foreign bodies (from Ø 12.5 mm).
It is not protected against the penetration of liquids. Therefore the equipment must not be
used in damp or wet rooms or outdoors in the rain. Always ensure that it is stored and used
in a dry place.
Penetration of foreign bodies and liquids can damage the unit and considerably
reduce its performance and service life.
Any other use or use that exceeds this is considered as not in accordance with the intended
purpose.
3.2.
Technical data
Performance
Capacity
pressure
Cylinder
Nr.
Model
Code
kW
PS
m³/min
cfm
MPa
Psi
Number
1
Z-0.036/7
cA51
0,55
0,75
0,036
1,3
0,7
102
1
2
V-0.08/7
VA51
1,1
1,5
0,08
2,8
0,7
102
2
3
Z-0.12/8
cD51
1,5
2
0,12
4,3
0,8
116
2
4
Z-0.17/7
VA55
1,5
2
0,17
6,0
0,7
102
2
5
V-0.25/7
VA65
2,2
3
0,25
8,9
0,7
102
2
6
W-0.36/7
TA65
3
4
0,36
12,8
0,7
102
3
7
V-0.48/7
VA80
4
5,5
0,48
17,0
0,7
102
2
8
W-0.67/7
TA80
5,5
7,5
0,67
23,8
0,7
102
3
9
V-0.67/7
VA100
5,5
7,5
0,67
23,8
0,7
102
2
10
W-0.9/7
TA100
7,5
10
0,9
31,9
0,7
102
3
11
W-1.4/7
TA120
11
15
1,4
49,6
0,7
102
3
The unit may not be used in explosive atmospheres. The compressor may only be operated
at ambient temperatures between 5-40 °C.
The suction of flammable gases etc. can lead to deflagration and explosions. This can
result in severe to fatal injuries and extensive damage to property.