Granit 61099050 Скачать руководство пользователя страница 5

 

 

Compressor Operating Instructions 

 

61099050 

 

3.

 

Performance specifications 

3.1.

 

Intended use 

The compressor is an oil lubricated air compressor. The ambient air is sucked in via the intake 
filter and cleaned. The air drawn in is then compressed in the cylinder. The compressed air 
flows into the pressure tank and is now available to supply the connected  compressed air 
tools. This compressor is designed exclusively for compressing air. 

NO flammable gases and/or paint and dust mist may be sucked in with this compressor. It 
may not be used in potentially explosive atmospheres as this may lead to serious or fatal 
accidents with high material damage. 

The suction of flammable gases etc. can lead to deflagration and explosions. This can 
result in serious to fatal injuries and extensive damage to property!  

The compressor has a finger guard and is thus protected against the penetration of medium-
sized foreign bodies (from Ø 12.5 mm).  

It is not protected against the penetration of liquids. Therefore the equipment must not be 
used in damp or wet rooms or outdoors in the rain. Always ensure that it is stored and used 
in a dry place. 

Penetration  of  foreign  bodies  and  liquids  can  damage  the  unit  and  considerably 
reduce its performance and service life. 

Any other use or use that exceeds this is considered as not in accordance with the intended 
purpose. 

3.2.

 

Technical data 

 

Performance 

Capacity 

pressure 

Cylinder 

Nr. 

Model 

Code 

kW 

PS 

m³/min 

cfm 

MPa 

Psi 

Number 

Z-0.036/7

 

cA51

 

0,55

 

0,75

 

0,036

 

1,3

 

0,7

 

102

 

1

 

V-0.08/7

 

VA51

 

1,1

 

1,5

 

0,08

 

2,8

 

0,7

 

102

 

2

 

Z-0.12/8

 

cD51

 

1,5

 

2

 

0,12

 

4,3

 

0,8

 

116

 

2

 

Z-0.17/7

 

VA55

 

1,5

 

2

 

0,17

 

6,0

 

0,7

 

102

 

2

 

V-0.25/7

 

VA65

 

2,2

 

3

 

0,25

 

8,9

 

0,7

 

102

 

2

 

W-0.36/7

 

TA65

 

3

 

4

 

0,36

 

12,8

 

0,7

 

102

 

3

 

V-0.48/7

 

VA80

 

4

 

5,5

 

0,48

 

17,0

 

0,7

 

102

 

2

 

W-0.67/7

 

TA80

 

5,5

 

7,5

 

0,67

 

23,8

 

0,7

 

102

 

3

 

V-0.67/7

 

VA100

 

5,5

 

7,5

 

0,67

 

23,8

 

0,7

 

102

 

2

 

10 

W-0.9/7

 

TA100

 

7,5

 

10

 

0,9

 

31,9

 

0,7

 

102

 

3

 

11 

W-1.4/7

 

TA120

 

11

 

15

 

1,4

 

49,6

 

0,7

 

102

 

3

 

 

The unit may not be used in explosive atmospheres. The compressor may only be operated 
at ambient temperatures between 5-40 °C. 

 

The suction of flammable gases etc. can lead to deflagration and explosions. This can 
result in severe to fatal injuries and extensive damage to property.  

 

Содержание 61099050

Страница 1: ...ctions Pump 61099050 These operating instructions must be read thoroughly before use and followed These Operating Instructions must be retained for future reference Translation of the original operati...

Страница 2: ...or 9 4 3 Operating a pressure tank 10 4 4 Operation at cold temperatures 10 4 5 Operating the equipment 11 4 6 Switching off the compressor 11 5 Maintenance and care 12 5 1 General maintenance instruc...

Страница 3: ...the item numbers in the tables Instructions for which the order must be followed are numbered 1 2 3 Lists are marked with bullet points Symbol labels on the device with their meaning Wear hearing pro...

Страница 4: ...operation residual hazards and risks become apparent which are not described in this manual the operator is obliged to report this to the manufacturer Do not change the setting of the safety valve Be...

Страница 5: ...ipment must not be used in damp or wet rooms or outdoors in the rain Always ensure that it is stored and used in a dry place Penetration of foreign bodies and liquids can damage the unit and considera...

Страница 6: ...t have the installation commissioned by a specialist Never loosen parts of the compressor while there is still compressed air in the container Sudden pressure release can lead to operating conditions...

Страница 7: ...glass Fig 4 no 13 Recommended compressor oil SAE30 or L DAB 100 for temperatures 10 C SAE10 or L DAB 68 for temperatures 10 C If the wrong oil is used or the oil level is incorrect this can damage the...

Страница 8: ...rally on the belt and press down The V belt is correctly tensioned when it can be pressed down approx 10 15 mm Make sure that the oil level is within the red indicator circle Recommended compressor oi...

Страница 9: ...he air in the vent pipe above the relief valve should be vented This prevents damage to the motor on restart The set pressure can be adjusted using the adjusting screw Fig 3 However this should not be...

Страница 10: ...maintenance and repair work without delay and take the safety measures that are needed under the circumstances In individual cases the competent supervisory authority may order the necessary monitorin...

Страница 11: ...consumption You can set the operating pressure with the pressure reducer Excessive working pressure leads to increased equipment wear without increasing the working performance To increase the working...

Страница 12: ...inal spare parts Fasteners must be regularly checked for tightness and tightened as necessary Never perform different kinds of work at the same time and with multiple people Failure to follow maintena...

Страница 13: ...Proceed as follows 1 Remove the air filter by unscrewing it from the air intake opening 2 Open the air filter housing and remove the foam filter 3 Clean the foam filter Do not use any cleaning agents...

Страница 14: ...as required by regional waste management regulations Improper disposal can cause considerable damage to the environment 6 Retighten the oil drain plug firmly after the used oil has all drained off 7 P...

Страница 15: ...efore it is stored and carry out maintenance before shutting it down so that the compressor is quickly ready for use again 7 Disposal The separate environmentally friendly disposal of materials encour...

Страница 16: ...parts worn out 1 Check and re fasten 2 Check and remove foreign body Insufficient pressure build up or reduced ventilation 1 Motor running too slowly 2 Air filter clogged 3 Safety valve leaking 4 Vent...

Страница 17: ...Compressor Operating Instructions 61099050 17 9 Component drawing with installation position Figure 4...

Страница 18: ...7 2 18 Ventilation pipe 61099050 18 1 19 Crankcase 61099050 19 1 20 Right angled connecting piece 61099050 20 1 21 Oil level gauge G1 2 61099050 21 1 22 Oil drain plug 61099050 22 1 23 Nut M8 61099050...

Страница 19: ...Spacer 61099050 53 3 54 Protective grille 61099050 54 1 55 Belt 61099050 55 1 56 Compressor belt pulley 61099050 56 1 57 Drain valve 1 4 inch 61099050 57 1 58 Rubber foot 61099050 58 2 59 Handle 6109...

Страница 20: ...trical equipment EC protection objectives were met according to Annex I No 1 5 1 of the Machinery Directive 2006 42 EC The machine also complies with the 2014 29 EU regulations on simple pressure tank...

Страница 21: ...4281 712 700 Postal and shipping address Wilhelm Fricke SE Zum Kreuzkamp 7 DE 27404 Heeslingen 14 Legal notice Original Operating Instructions for a Compressor Model 61099050 Manufacturer Wilhelm Fri...

Отзывы: