Grand Effects
360 Fire-Water Bowls and Fire-Water Inserts (Automated Operation)
Operating and Maintenance Instructions
Section 3: Burner Setup and Adjustment
1.
At the control panel, turn the manual gas valve to the “Off” position.
2.
With 120
VAC
coming into the control panel, turn the burner switch “On.”
3.
At the
burner assembly, check that the spark electrode is arcing across to the
pilot hood. You should be able to hear and see the electrode spark. If there is no
spark, make sure that the burner assembly is receiving 12
VAC from the control
panel.
4.
Reposition the burner assembly so that it is sitting level in the bowl.
5.
At the control panel, open the manual gas valve.
6.
In the control panel, turn the burner switch to the “On” position.
7.
After the burner has
been lit,
it
can be adjusted for flame size.
Important:
At this time, the 360 fire-water
bowl should ignite. If the burner does
not light, it may be a result of air in the gas line. If this happens, carefully purge
the air from the gas line by disconnecting the gas hose from the burner
assembly. The end of the gas hose should be outside of the bowl when purging
air from the gas line.
CAUTION!
When purging air from a propane system, disconnect wires going to
the burner assemblies (terminals X1/X2) located in Grand Effects control
panel.
There should be no power
at the burner assemblies when purging propane. The
propane adder valve should remain wired and energized when purging. After
purging is complete, make sure the area is vented and free from built-up gas.
Reinstall wires at X1/X2 terminals, thus providing
power
to burner assemblies.
Figure 9: Bottom Side of the Burner Assembly
www.grandeffectsinc.com
949-697-5270
8