Heating & Cooling
154
Air Conditioner, Continued
Air conditioner gasket
A special foam gasket is placed between the roof material and
the sub-frame of the air conditioner to weatherproof the seal.
The air conditioner is subjected to wind pressures along with
motor vibration during normal operation.
Inspect the gasket seal (at least) annually. Check for leaks and
re-tighten the mounting bolts if needed. To prevent damage to
the gasket, be careful NOT to
over-tighten
the bolts.
The air conditioner gasket is a wearable part that eventually
will need replacement. To gain access to the bolts, remove the
filtered panel cover on central air systems or the entire air box
on non-central air conditioners.
Heat pump (If So Equipped)
A heat pump is one base unit that can operate in two modes,
heating or cooling. The travel or flow of the refrigerant is reversed
depending on which cycle you choose to operate:
• Cooling Mode: Heat is removed from the
inside
air
and released to the
outside
air.
• Heating Mode: Heat is removed from the
outside
air
and released to the
inside
air.
Furnace
The RV furnace installed in the RV is controlled by a thermostat.
The furnace requires both 12-volt power and propane gas for
full operation. Make sure you have sufficient power available
before operating your furnace.
• ALWAYS have your furnace maintenance completed by
a qualified technician (at least once a year, more often
depending on furnace use).
• NEVER attempt to repair the furnace yourself.
If you have any questions, Contact your dealer or
Grand Design Customer Service.
The furnace should be
inspected periodically
(
monthly
during the heating
season) for the presence
of soot on the vent.
Soot is formed whenever
combustion is incomplete.
This is a visual warning that
the furnace is operating in
an unsafe manner.
If soot is observed on the
vent, IMMEDIATELY shut the
furnace OFF and contact
a qualified service agency.
Operating the furnace
under this condition could
lead to serious property
damage, personal injury or
loss of life.
To ensure your personal
safety, DO NOT obstruct
or alter the furnace in any
manner. Do not install
screens over the vent for
any reason. Screens will
become restricted and
cause unsafe furnace
operation. For your
safety, only OEM factory
authorized parts are to be
used on your furnace.
WARNING
WARNING
DO NOT operate the furnace
when the slide rooms are
retracted in the closed
position.
WARNING
Содержание Reflection Fifth Wheel 150 Series
Страница 1: ...O W N E R S M A N U A L ...
Страница 2: ......
Страница 4: ...This page is intentionally blank ...
Страница 6: ...This page is intentionally blank ...
Страница 31: ...This page is intentionally blank 25 ...
Страница 34: ...This page is intentionally blank 28 ...
Страница 72: ...66 ...
Страница 110: ...This page is intentionally blank 104 ...
Страница 142: ...This page is intentionally blank 136 ...
Страница 166: ...160 This page is intentionally blank ...
Страница 214: ...208 Customer Notes ...
Страница 215: ...209 Customer Notes ...
Страница 216: ...210 Customer Notes ...
Страница 217: ...211 Customer Notes ...
Страница 218: ...212 Maintenance Record Maintenance Record Date Work Performed Next Service ...
Страница 219: ......