background image

  BED ROCK BURNER INSTALLATION & OPERATION MANUAL 

GRANDCANYONGASLOGS.COM - 06_2021

SAFETY INFORMATION

p

 WARNING

• Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this appliance.
• This appliance must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.
• Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance 

and to replace any part of the control system and any gas control which has been under water.

• Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with all plastic bags,  

these are not toys and should be kept away from children and infants.

• Carbon monoxide poisoning may lead to death; early signs of carbon monoxide poisoning resemble the flu, with headache,  

dizziness and/or nausea. If you have these signs, the appliance may not be working properly. Get fresh air at once! Have  

appliance serviced. Some people; pregnant women, persons with heart or lung disease, anemia, those under the influence of  

alcohol, those at high altitudes are more affected by carbon monoxide than others. Failure to keep the primary air opening(s)  

of the burner(s) clean may result in sooting and property damage.

• As with any combustion appliance, we recommend having your appliance regularly inspected and serviced as well as having a 

Carbon Monoxide Detector installed in the same area to defend you and your family against Carbon Monoxide (not applicable for 

outdoor appliances).

• Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance. Elevated temperatures 

on the wall or in the air above the appliance can cause melting, discolouration or damage to decorations, a TV or other electronic 

components.

• For appliances equipped with a safety barrier; if the barrier becomes damaged, the barrier shall be replaced with the  

manufacturer’s barrier for this appliance.

• Installation and repair should be done by a qualified service person. It is imperative that control compartments,  

burners and circulating air passageways of the appliance be kept clean.

• For outdoor products only: this appliance must not be installed indoors or within any structure that prevents or inhibits the exhaust 

gases from dissipating in the outside atmosphere.

  

This product can expose you to chemicals including lead and lead compounds, which are known to the 

State of California to cause cancer, and chemicals including carbon monoxide, which are known to the State of California to cause 

birth defects or other reproductive harm.  For more information, go to www.P65Warnings.ca.gov.

FIRE RISK HAZARD / DELAYED IGNITION 

High supply pressure will damage the valve / controls. 
Disconnect the appliance main gas valve/control from 

the supply piping when pressure testing that system at 

pressures in excess of 1/2 psi (3.5 kPa).
Isolate the appliance with it’s shut off valve during 

any pressure testing of the supply piping at pressures 

equal to or less than 1/2 psi (3.5 kPa).

  

Improper installation, adjustment, service or maintenance can cause property damage, personal injury, 

or loss of life. Refer to the Owner’s Information manual provided with this appliance.  Installation and service must be performed by 

a qualified installer, service agency or the gas supplier.

  

Vented Decorative Gas Appliance: Not a source of heat; Not for use with solid fuel.  This appliance needs 

fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

  

This appliance is NOT for installation in manufactured or mobile homes.

  

Do not use the appliance if any part has been under water.  Immediately call a qualified service techni-

cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

3

  

Failure to position the parts in accordance with these diagrams or failure touse only parts specifically 

approved with this appliance may result in property damage or personal injury.

Содержание LDB24B-EN

Страница 1: ...e vicinity of this or any other appliance INSTALLER Leave this manual with appliance CONSUMER Retain this manual for future reference WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supp...

Страница 2: ...rfaces Even after the appliance is off it will remain hot for an extended period of time Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces These screens and guards must be fastened to the floor Any safety screen guard or barrier removed for servicing the appliance must be replaced prior to operating the appliance A fireplace sc...

Страница 3: ...eplaced with the manufacturer s barrier for this appliance Installation and repair should be done by a qualified service person It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean For outdoor products only this appliance must not be installed indoors or within any structure that prevents or inhibits the exhaust gases from dissipating in...

Страница 4: ...ctions 5 Parts List 8 Wiring Diagram Pre Installation 9 Installation Steps 10 Multifunction Remote Operating Instructions 11 Wi Fi Multifunction Remote Operating Instructions 15 Intermittent Pilot Instructions 16 Maintenance 17 Troubleshooting 18 Warranty 20 NOTE Changes other than editorial are denoted by a vertical line in the margin 4 ...

Страница 5: ...BED ROCK BURNER INSTALLATION OPERATION MANUAL GRANDCANYONGASLOGS COM 06_2021 GENERAL INSTRUCTIONS 5 SAMPLE SAMPLE ...

Страница 6: ... constructed of non combustible material Appliance Input Rate kBTU hr Chimney 20 30 40 50 60 70 80 90 100 110 120 Maximum Height ft Minimum opening in2 Input 10 11 3 16 6 22 11 28 3 35 3 44 2 77 6 15 8 6 12 6 17 3 21 2 26 4 32 2 38 5 45 4 98 2 20 7 5 10 8 14 5 18 1 22 1 26 4 31 2 37 4 43 114 2 25 6 6 9 6 12 6 15 9 18 1 22 9 27 3 31 2 36 3 43 50 3 121 30 6 2 9 1 11 3 14 5 17 3 20 4 24 6 28 3 33 2 3...

Страница 7: ...BED ROCK BURNER INSTALLATION OPERATION MANUAL GRANDCANYONGASLOGS COM 06_2021 GENERAL INSTRUCTIONS 7 Burner Specifications LIQUID PROPANE MODELS NATURAL GAS MODELS LP Models NG Models ...

Страница 8: ...LAME 2 P 15 PO 16 ELEC 17 PROFLA 18 PROFLAME 19 20 PROFLAME 21 LE 22 PROFL DO NOT SCALE DRAWING UNLESS OTHERWISE SPECIFIED Q A MFG ENG CHE DRA FINISH MATERIAL INTERPRET GEOMETRIC TOLERANCING PER DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL ANGULAR MACH 1 BEND 1 TWO PLACE DECIMAL 010 THREE PLACE DECIMAL 005 P THE I DRAW MOD IN PA WITH MOD A B 4 3 2 Glass media NOT INCLUDED refer to installation i...

Страница 9: ... any damage Contact your retailer if any damage is found Do not install your appliance with any damage or substituted parts The installation of your Bed Rock Burner will follow the steps listed Pre Installation planning ensure the opening of the fireplace meets the specification Page 7 Electric installation Right side 6 cord Gas installation Preferred left side Installing the burner Before you beg...

Страница 10: ...connect to burner assembly gas valve Use soapy water to check connections for leaks Longer gas connector maybe needed for unique installations not provided Figure 3 1 3 2 Place batteries in the battery holder and both remotes Remotes are synced at factory prior to shipping To re sync the ProFlame II remote review the remote section of the manual Page 12 Pull up on the handles located on the left a...

Страница 11: ...BED ROCK BURNER INSTALLATION OPERATION MANUAL GRANDCANYONGASLOGS COM 06_2021 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS 11 ...

Страница 12: ...ROCK BURNER INSTALLATION OPERATION MANUAL GRANDCANYONGASLOGS COM 06_2021 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS 12 Figure 7 3 7 1 Figure 7 4 7 2 Figure 7 1 7 3 7 2 7 2 Figure 7 5 7 4 and 7 5 Figure 7 2 ...

Страница 13: ...BED ROCK BURNER INSTALLATION OPERATION MANUAL GRANDCANYONGASLOGS COM 06_2021 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS 13 Figure 7 6 7 6 Figure 7 7 Figure 7 8 Figure 7 9 Figure 7 10 7 7 through 7 10 ...

Страница 14: ...n on off command The system will not accept any commands until the batteries are replaced or A C power is restored Lockout State Definition To prevent damage to the fireplace IFC board will automatically lock out the remote control if it detects a anomalous flame or too many unsuccessful ignition attempts The lockout state will remain as long as the power supplies are applied When the IFC board go...

Страница 15: ...BED ROCK BURNER INSTALLATION OPERATION MANUAL GRANDCANYONGASLOGS COM 06_2021 Wi Fi APP MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS 15 Download to your mobile device ...

Страница 16: ...ician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Read the Care and Operation manual including the section on Remote Control System 3 Press ON OFF button on remote control transmitter to OFF 4 Turn OFF all electric power to the appliance 5 This ap...

Страница 17: ...re to properly position the media may cause carboning which can be distributed in the surrounding living area inside the firebox and on exterior surfaces surrounding vent termination 8 Check to see that the main burner ignites completely on all ports when turned on A 5 to 10 second total light up period is satisfactory If ignition takes longer consult your local authorized dealer distributor 9 Vis...

Страница 18: ...iter wire from the module Place the ON OFF switch to the ON position Hold a grounded wire about 3 16 4 8mm away from the ignitor spark terminal on the module If no spark the ignitor termi nal module must be replaced If there is a spark the ignitor terminal is fine Spark gap of the ignitor to the pilot should be 1 8 3 2mm Inspect pilot assembly for a shorted wire or cracked insulator around the ele...

Страница 19: ...circuit is broken A wrong orifice or too high of an inlet pressure can cause the pilot to lift The sensor rod may need cleaning Verify that the wire harness is firmly connected to the module Verify that the ceramic insulator around the sensor rod is not cracked damaged or loose Verify the connection from the sensor rod to the sensor wire Clean sensor rod with an emery cloth to remove any contamina...

Страница 20: ...ch the burner was originally purchased Batteries are not covered under this warranty ODS pilot assemblies carry a 1 year warranty WARRANTY CARD Please fill this warrant card and mail it to Grand Canyon Gas Logs to receive a warranty claim Purchased from Showroom name ____________________________________________________________________ City __________________________________________________________...

Страница 21: ...ith installation product information or if your product arrives damaged please call our toll free number at 1 602 344 4217 Monday Friday 8 00AM 5 00PM AZ Mountain Time or email us at customerservice grandcanyongaslogs com OUR STAFF IS READY TO PROVIDE ASSISTANCE Copyright 2021 All rights reserved U S A and Foreign Patents Pending 062021_V1 ...

Отзывы: