Gram GEC Series Скачать руководство пользователя страница 1

 
 
 
 

OPERATION MANUAL 

 

 

 
 

SERIES GEC 

Models 

                                         GEC-6 
                                      GEC-15 

    GEC-30 

 

 

 
 
 
 
 
 
 

REV. 1A9M06 

Содержание GEC Series

Страница 1: ...OPERATION MANUAL SERIES GEC Models GEC 6 GEC 15 GEC 30 REV 1A9M06...

Страница 2: ...mm 245 x 355 W x H Dimensions mm 387 x 365 x 117 W x L x H Net weight kg 3 7kg Operation temperature 0 to 40 RH Less than 85 Power 9V 500mA AC adaptor rechargeable battery 6V Output RS 232C Model GEC...

Страница 3: ...y Total pieces display Indicates that battery voltage is low the battery must be charged Indicates that display shows the net weight after making a tare Indicates that weight is stable Indicates that...

Страница 4: ...es that the high limit of a weight or number of pieces has been configured Indicates that the low limit of a weight or number of pieces has been configured KEYBOARD DESCRIPTION To turn off the scale T...

Страница 5: ...ess this key to save introduce or modify the weight of a sample Memorizes the unit weight of a sample Memorizes the number of pieces of a sample Change the indicator from the scale pan A to external p...

Страница 6: ...splay is at zero 2 Press the key the second display will show and the third will show by default as 100 3 Use the numerical and decimal keys to input the quantity of pieces 4 Place the pieces on the w...

Страница 7: ...remove pieces and press the key to calculate again the unit weight Auto sampling operation After the sampling introduction the scale will automatically do the sampling in mode A scale of any small ite...

Страница 8: ...ol will flash 4 Press the PLU key to confirm after a bip the unit weight for PLU 15 will be of 0 5 g Configuration of indirect PLU s 0 999 1 Input the unit weight of the piece see sampling introductio...

Страница 9: ...ber 15 will be automatically recalled The display will show 15 below Recall of an indirect PLU 0 999 1 In normal weighing mode keep pressed the PLU until the scale gives a double beep then release the...

Страница 10: ...t save the data of following weighing l The scale can store up to 180 weighings Total weighing accumulations MR 1 In weighing mode press the MR key the display WEIGHT will remain at zero The display P...

Страница 11: ...ll show Input the high limit for weight using the numerical keyboard The unit weight must be in grams 5 Press the ALARM key The display PCS will show the message Input the low limit for weight using t...

Страница 12: ...y to activate the scale A or the auxiliary platform B 2 The initial zero is the zero configured in calibration procedure It means that the weight located on the pan will be displayed accurately when t...

Страница 13: ...is necessary to remove the JP3 jumper from PCB Once the configuration is completed place the JP3 jumper in the original place again GENERAL CONFIGURATION CAL 1 Press the C key to navigate through diff...

Страница 14: ...ions rE tArE oFF Tare repetition disabled rE tArE on Tare repetition enabled 4 rE SAnP AUTO SAMPLING Display Descriptions rE SAnP oFF Auto sampling function disabled rE SAnP on Auto sampling function...

Страница 15: ...it alarm Sound format continuous short beeps Lo bEEP ALArn LonG Low Limit alarm Sound format continuous long beeps 7 ZERO TRACKING Display Descriptions trAcE oFF Zero tracking disabled trAcE on Zero t...

Страница 16: ...S Add Press the M key to accumulate the weight only 11 ACCUMULATED TOTAL Display Descriptions Nr rEC LEAuE Press the MR key to view the accumulated total Pressing it again will delete the accumulation...

Страница 17: ...ion of the auxiliary platform resolution d in grams Min d is 1 gram Max d is 65535 grams 3 Configuration of stability level auxiliary platform B Display Descriptions b StAbL x 1 10 Configuration of th...

Страница 18: ...the value of the calibration weight in grams 3 When the AD value is stable press the key to complete the calibration PRINT CONFIGURATION CAL 3 This section is only applicable in models with RS 232C d...

Страница 19: ...key to print out the net weight when the scale is stable and the weight is 0 Press the MR key to not print Print ALL 1 Press the M key to print out a single weighing Press the C key within MR mode to...

Страница 20: ...Descriptions Kg Lb Viewed max capacity varies with the default wt unit LoAd 03 LoAd 06 Configure maximum capacity as 3 kg 6lb LoAd 06 LoAd 12 Configure maximum capacity as 6 kg 12lb LoAd 15 LoAd 30 C...

Страница 21: ...the AD value is stable press the key to conclude the calibration process LINEARITY CALIBRATION CAL 5 Note This section can only be carried out by professionals Remove the JP3 jumper before proceeding...

Страница 22: ...e second row shoes the calibration weight value of 1 3 of maximum capacity Unit grams or lb 1000 and the third one shows Pnt 1 Place the corresponding calibration weight with the value of 1 3 of the s...

Страница 23: ...irst row shows the AD value the second row shows the maximum capacity value Unit grams or lb 1000 and the third one shows the Pnt 3 message Place the calibration weight corresponding to maximum capaci...

Страница 24: ...o subtract the result of a single weighing SUBRACT COUNTING Net Weight Weight format Piece Weight Weight format3 Piece Count Count format 2 To print the accumulation of weighings when the total total...

Страница 25: ...alue is 123 456 Z Zeroing the display reading M Storing the results in the memory and printing MR Recovering the values from the memory MC Deleting the data from the memory U123 456 Storing the unit w...

Страница 26: ...LU command the data are PLU number 3 characters Comma description max 18 characters l If the fields are less than maximum it will not be necessary to use all the characters WARRANTY This scale is cove...

Страница 27: ......

Страница 28: ......

Отзывы: