"Defrost", Afrimningsparameter
Parameter
Description
Setting range
Default
d
"Defrost": Afrimning
d1
No. of defrosts / 24 hours
1 … 8
4
d2
Defrost temperature limit
0 til 30 °C
12
d3
(”manual”) initial defrosting
0 = On / 1 = Off
0
d4
Maximum defrost time
10 … 60 min.
30
d5
Defrost mode
1 = automatic
(depending on setting "d7")
2 = air
3 = electric (defrost heater)
3
d6
Drip time
0 …10 min.
2.
d7
Temperature limit at
automatic defrosting
at "d5" = 1:
+2 … +25°C
+4
d8
Evaporator monitoring, if
exceeding, forced defrosting
follows
-5 .. -50 °C
-40
d9
Defrosting by termination of
"PCL", "HCL", "SCL"
0 =On ... 1 =Off
1