765041559 

Rev. 002

 

 
 

 
Thank you for choosing a quality product from Gram Commercial. 
 
This manual will advise you how to install, use and maintain your new product. 
 
Before our products leave the factory, they undergo a full function and quality test. 
 
Should you nevertheless experience problems with the product, then contact your local dealer. Gram 
Commercial representatives and dealers placed all over the world are ready to help you. 
 
Please refer to your dealer for information about the warranty coverage of your new Gram product. 
 
Any warranty is subject to correct use according to specifications in this user manual, where e.g. common 
maintenance and eventual repairs are carried out by authorized technicians with proper knowledge of the 
product and only using original spare parts. 
 
Changes in installation and other use of the product than prescribed in this manual, might affect the 
operation and durability of the product. 
 
The manual is written according to our current technical knowledge. We constantly work on updating this 
information, and we reserve the right to make technical changes. 
 
 
 

Intended use 

 

 
The product is designed for professional storage of foodstuff at a constant temperature.  

The product is not be used for chilling down or freezing in foodstuff. 

The product is only to be used for the purpose for which it has been expressly designed. Any other use could 
cause that the foodstuff stored in the product are not kept at the correct temperature or even damage the 
product. 

The product is not suited for storing blood plasma, laboratory samples, pharmaceuticals or similar 
substances. The manufacturer will not be held liable or responsible for any damage caused by improper, 
incorrect or unreasonable use of the product. 
 

Содержание 866100635

Страница 1: ...1 765041559 Rev 002 Operating and servicemanual Compact 610...

Страница 2: ...LOCATION 12 OPTIMIZING THE ENERGY CONSUMPTION 14 GENERAL DESCRIPTION 15 REFRIGERANT GWP VALUE 16 CLIMATE TEMPERATURE CLASS 16 ELECTRICAL CONNECTION 17 GENERAL USE 18 STARTING UP 20 TEMPERATURE SETTIN...

Страница 3: ...cluding compressor Cabinets without compressor FAV is given by the symbol The symbol means Compressor not included Because program variants like K and M is difficult to present in a 7 segment display...

Страница 4: ...ature will change one degree When the display shows the desired temperature let go of the two keys and the setting has been made By keeping pressed the digits change fast Temperature down Keep pressed...

Страница 5: ...keep running until the error has been mended F3 Condenser sensor error The cabinet will keep running until the error has been mended Service assistance is required F7 Indicates that the condenser temp...

Страница 6: ...rm the display shows A1 1 on 0 off dAd min Time delay for the door alarm BU On off Activation of buzzer The buzzer sounds at alarms A1 A2 1 on 0 off External alarm setting EAL EHL C Setting the upper...

Страница 7: ...am Push on button to activate the desired relay and the display glows with on The desired relay conducts now power to the electrical component Push the button to switch off the power from the electric...

Страница 8: ...t relay K4 The relay supplies the halogen light transformer with power 230V 12V 10 230 Volt relay K7 and K8 The relay supplies the front frame heater re evaporating heating element and the condensing...

Страница 9: ...use the controller lets the evaporator fans keep running By shortcutting the terminals the fan stops 21 A Room sensor input NTC sensor B Evaporator sensor input NTC sensor C Condenser sensor input 1 N...

Страница 10: ...ginal spare parts Changes in installation and other use of the product than prescribed in this manual might affect the operation and durability of the product The manual is written according to our cu...

Страница 11: ...the product to have access to this manual This appliance is not intended for use by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have b...

Страница 12: ...nsport pallet The cabinet is tilted slightly backward and the front part of the pallet can be removed Then the cabinet is tilted slightly forward and the rear part can be removed This task requires at...

Страница 13: ...d placement of the cabinet in a chlorine acid containing environment swimming bath etc due to risk of corrosion The cabinet and parts of the interior is equipped with a protecting film which should be...

Страница 14: ...operate in an ambient temperature between 16 C and 40 C Do not keep the door open for too long Keep the condenser filter clean to be cleaned at least every 2 weeks Do not set the temperature setpoint...

Страница 15: ...15 765041559 Rev 002 General description Compressor Condenser with air filter Control panel Display Air inlet Shelves for storage Door Door gasket Air distribution plate Fig 6...

Страница 16: ...430 329 Freezers F 610 G R290 0 092 3 0 3 F 610 H R404A 0 220 3922 863 MARINE F 610 H R452A 0 220 2140 471 Climate temperature class Products are tested according to the following climate and temperat...

Страница 17: ...e If a wall socket is placed in a longer distance than the length of the supplied power cord contact an electrician to establish a wall socket within the range of the supplied power cord If the produc...

Страница 18: ...rts of the cabinet General use Do not block vent holes in the front panel Do not damage the refrigeration system parts During normal operation some parts of the refrigeration system in the compressor...

Страница 19: ...some space between them to ensure a good airflow Moist or fresh foods and those with a strong smell should be wrapped up in a plastic film or packed in a container Foods containing acetic acid or yeas...

Страница 20: ...pped shortly after when the system has performed a system check To cancel the defrost program press keys P and for more than 3 seconds is turned off To turn off the cabinet push for more than 3 second...

Страница 21: ...e by the memory of the controller Temperature stability will be affected Service assistance is required F2 Evaporator sensor error Service assistance is required The cabinet will keep running until th...

Страница 22: ...ing into a locking system The locking system could be locked unintentionally then the catch can be extracted with a tool Frosting inside compartment Ambient humidity too high The door is opened too of...

Страница 23: ...inet temperature setting too low Cabinet too packed with foods air inlet outlet blocked Condenser mesh filter is clogged Warm or hot foods are brought into the cabinet too often Cabinet placed in dire...

Страница 24: ...on off Activation of rapid thaw on off Local alarm setting LAL LHL C Setting the upper alarm limit At alarm the display shows A2 LHd min Time delay for the upper alarm limit dA On off Activation of l...

Страница 25: ...defrosting can become necessary Starting manual defrosting push P simultaneously for more than 3 seconds The next defrost will occur 6 hours later It is possible to change the number of defrosts See t...

Страница 26: ...wer failure In the event of a power failure the control remembers the temperature setting and restarts the cabinet when power is restored If the power failure persists for some time the control might...

Страница 27: ...removed and cleaned in a dishwasher at max 50 C F evt reng ring af kondensatoren noteret i reng ringsplanen For the external maintenance use stainless steel polish The cabinet should be cleaned inter...

Страница 28: ...t has been unintentionally disconnected or switched off at the socket or whether a fuse has blown If it is not possible to find the cause of the refrigeration failure please contact your dealer When r...

Страница 29: ...of use This will prevent the uncontrolled escape of the refrigerant from the refrigeration system The below only concerns the United Kingdom Disposal of an old cabinet is only available when we are de...

Страница 30: ...65 EU RoHS 3 EU 2015 863 Standards The following standards are used to the extent necessary to comply with the relevant directives DS EN 12100 2011 Safety of machinery General principles for design R...

Страница 31: ...31 765041559 Rev 002 Wiring diagram...

Страница 32: ...32 765041559 Rev 002 Piping diagram...