10/24
GrainPro
®
Gas-Hermetic Fumigation/Self-Verifying Cocoon™ Instruction Manual
MA2021TDB1199-19
5.3.3. One pair of arrows is painted green. Match these arrows for correct front and back orientation
of the Cocoon.
5.3.4. Pull the sides all the way down over the stack.
5.3.5. Do not use tensions straps to pull or carry the top section.
5.4.
USE OF DESICCANT (CALCIUM CHLORIDE, CaCl
2
)
– (Recommended)
5.4.1. Required dosage of Calcium Chloride, CalCl
2
.
5.4.2. Place the packed desiccant (Calcium Chloride, CaCl
2
), at the middle-top portion of the
bags inside the SVC G-HF before Zipping.
5.4.3. If it will be in six(6) months of storage, spread-out the packed desiccant (Calcium Chloride,
CaCl
2
) at the top portion of the bags inside the SVC G-HF before Zipping.
G-HF COCOON
CAPACITY
Desiccant Require (CaCl
2
)
for 1month of Storage
Desiccant Required (CaCl
2
)
for 6months of Storage
(MT)
grams
grams
GP G-HF Cocoon-005
5
50
300
GP G-HF Cocoon-010
10
100
600
GP G-HF Cocoon-020
20
200
1200
GP G-HF Cocoon-2-050
50
600
3600
GP G-HF Cocoon-3-050
50
600
3600
GP G-HF Cocoon-100
100
1000
6000
GP G-HF Cocoon-3-150
150
1600
9600
GP G-HF Cocoon-4.5-150
150
1600
9600
GP G-HF Cocoon-300
300
3000
18000
5.5.
ZIPPING
5.5.1. Preparing to zip:
a. Insert one hand inside the inverted
pocket and engage the zipper track for
the top and bottom liners by pressing
the zipper against the other hand.
b. Manually close the zipper track to a
length of 10cm before using the zipper
pull
NOTE:
▪
There are zipper pulls that zip to the right for right-
handed users [marked with “RIGHT”]
and zipper pulls that zip to the left for left-
handed users [marked with “LEFT”], select the
direction with which you are most comfortable.
5.5.2. Engaging the zipper pull:
a. Open the zipper mechanism by moving
the black plastic handle projecting from
the large wheel away from the flexible
pulling loop.