2 7 5 F
R E E D O M
8–11
Portable Head With In-line Macerator
There are two ways to empty the portable head reservoir with this type of set-up. The waste
may be vacuumed out through the deck fitting or discharged through a seacock in the hull
bottom. The macerator pump and Y-valve are located beneath the rigging lid between the
consoles.
Using Deck Pump-Out
1. Locate the Y-valve mounted on the forward bulkhead in the forward bilge compartment.
Place the Y-valve handle in the deck pump-out position.
2. Remove the cap from the deck pump-out fitting located in the starboard walkaround.
3. Connect a vacuum hose from a pump-out station to the deck fitting and run until the reser-
voir is empty. Replace the cap on the deck pump-out fitting.
Using Discharge Seacock (Overboard)
1. Locate the Y-valve mounted on the forward bulkhead in the forward bilge compartment.
Place the Y-valve handle in the overboard discharge position.
2. Open the head discharge seacock by pulling up on the remote seacock arm. This seacock is
located under the access plate in the forward bilge compartment.
3. Turn “on” the head pump switch at the helm and discharge until the reservoir is empty.
Close the discharge seacock (handle in the horizontal position).
“Portable Head With In-line Macerator” on page 8–27
for a layout diagram.
L
IVEWELL
- R
AW
W
ATER
To operate the livewell, open the seacock with the livewell I.D. tag located in the port aft
bilge. The livewell pump is screwed directly into this seacock. The livewell switch at the helm
should be in the on position. Place the livewell standpipe in the drain located at the bottom of the
livewell. Screw it down until the black flange makes contact with the flange on the drain fitting.
Water will enter through a plenum along the side of the livewell and be distributed through a
series of holes arranged vertically along the plenum. The water will rise to a depth even with the
strainer on the standpipe and drain overboard. To evacuate debris and bait waste from the bottom
of the box while the livewell is in operation, unscrew the standpipe approximately three turns to
expose two 3/8” holes located in the threads of the standpipe base. This will allow a small amount
of water to escape through these holes and remove any waste that has settled in the bottom of the
livewell. See
“Livewell/Washdown Layout” on page 8–24
N O T I C E
Overboard discharge seacock must be secured in the “closed” position in accordance with the
laws in your boating area.