C
O A S T A L
E
X P L O R E R
2 5 1
8–5
H
EAD
Portable Head Operation
1. The upper freshwater reservoir must be filled with water prior to use. Compress the bellows
pump located on the left corner of the toilet a few times to add water to the bowl.
2.
Flush
the toilet by pulling the slide valve handle out (located on the front of the toilet).
3. Compress the bellows pump until the bowl is rinsed.
4. Close the slide valve handle by pushing it in fully.
L
IVEWELL
- R
AW
W
ATER
The 251 is equipped with a livewell in the aft box just forward of the motorwell and has an
optional livewell located under the starboard seat of the deluxe leanbar. To operate either livewell,
first open the seacock with the livewell I.D. tag located in the port aft rigging compartment under
the storage insert. If the boat is equipped with both livewells and has two seacocks, the seacock
closest to centerline is for the leanbar livewell. The livewell pumps are threaded directly into the
seacocks. For the aft livewell, plug the drain in the bottom of the livewell and place the “aft
livewell” switch at the helm in the “on” position. Water will enter the box through the inlet fitting,
rise until it reaches the overflow drain, and then drain overboard. For the leanbar livewell, place
the standpipe in the drain at the bottom of the livewell. Screw it down until the black flange makes
contact with the flange on the drain fitting. Place the “leanbar livewell” switch at the helm in the
“on” position. Water will enter through a plenum along the side of the livewell and be distributed
through a series of holes arranged vertically along the plenum. The water will rise to a depth even
with the strainer on the standpipe and then drain overboard. To evacuate debris and bait waste
from the bottom of the box while the livewell is in operation, unscrew the standpipe
approximately three turns to expose two 3/8” holes located in the threads of the standpipe base.
This will allow a small amount of water to escape through these holes and remove waste that has
settled in the bottom of the livewell. See
“Livewell Layout” on page 8–17
M
AIN
C
IRCUIT
B
REAKER
There is a 50 amp circuit breaker located in the aft starboard rigging compartment beneath the
removable storage insert. This is the main breaker protecting the wiring supplying power to the
helm switch panel. If this breaker is tripped, move the yellow lever to the vertical postition to
reset it.
N O T I C E
If the livewell seacock is left open and the pump is not on, the boats forward motion through the
water will gradually fill the box. To prevent this inadvertent filling, close the seacock when the
livewell is not in use.
Under certain conditions, placing the outboard engine(s) in reverse will ventilate the water under
the boat and create an air lock in the livewell pump. To prevent this situation from occurring, it is
recommended the livewell be turned off prior to any high RPM or continuous reverse operation.
If the livewell pump becomes air-locked, correct this situation by turning the pump off for 20
seconds.
Содержание Coastal Explorer 251
Страница 2: ......
Страница 6: ...T A B L E O F C O N T E N T S ...
Страница 10: ...W E L C O M E 1 4 ...
Страница 24: ...G E N E R A L I N F O R M A T I O N 3 6 ...
Страница 32: ...I N S T R U M E N T A T I O N A N D S W I T C H E S 5 4 ...
Страница 42: ...M A I N T E N A N C E A N D S E R V I C E 6 10 ...
Страница 68: ...C O A S T A L E X P L O R E R 2 5 1 8 22 ...
Страница 72: ...L I M I T E D W A R R A N T Y 9 4 ...