The 191 has an optional pressurized freshwater system. The freshwater pump is activated by
the freshwater switch on the helm switch panel, and supplies water from the 10 gallon (37.9 L)
water tank to the cockpit shower. The freshwater pump is located on the port side of the aft
rigging compartment. The water tank is located under the poly lid in the console. Reference
“Freshwater System Layout” on page 8–15
L
IVEWELL
- R
AW
W
ATER
The 191 is available with two different livewell options. One livewell option is installed in the
aft box just forward of the motorwell. The other livewell is installed in the forward console box.
To operate either livewell, first open it’s respective seacock with the livewell I.D. tag. Both
livewell seacocks are located in the aft rigging compartment. The aft livewell seacock is beneath
the port storage insert while the foward livewell seacock is beneath the starboard storage insert.
The livewell pumps are threaded directly into the seacocks. Next, the helm switch for the livewell
you want to operate should be in the "on" position. Water will enter the livewell through the inlet
fitting and rise until it reaches the overflow drain. Then, it will drain overboard at a thru-hull
fitting. See
“Livewell Layout” on page 8–17
C A U T I O N
The freshwater system is not a potable water source. Do not use the water from the freshwater
outlets on your boat for drinking purposes. The quality of the water is dependent upon the
cleanliness of the water tank and other components of the freshwater system. The label pictured
below can be found at all freshwater and raw water outlets on your boat. Contact your dealer for
replacement labels.
N O T I C E
If the livewell seacock is left open and the pump is not on, the boats forward motion through the
water will gradually fill the box. To prevent this inadvertent filling, close the seacock when the
livewell is not in use.
Under certain conditions, placing the outboard engine(s) in reverse will ventilate the water under
the boat and create an air lock in the livewell pump. To prevent this situation from occurring, it is
recommended the livewell be turned off prior to any high RPM or continuous reverse operation.
If the livewell pump becomes air-locked, correct this situation by turning the pump off for 20
seconds.
!
Содержание Coastal Explorer 191
Страница 2: ......
Страница 6: ...T A B L E O F C O N T E N T S ...
Страница 10: ...W E L C O M E 1 4 ...
Страница 24: ...G E N E R A L I N F O R M A T I O N 3 6 ...
Страница 32: ...I N S T R U M E N T A T I O N A N D S W I T C H E S 5 4 ...
Страница 42: ...M A I N T E N A N C E A N D S E R V I C E 6 10 ...
Страница 68: ...C O A S T A L E X P L O R E R 1 9 1 8 22 ...
Страница 72: ...L I M I T E D W A R R A N T Y 9 4 ...