Operation
3A6283F
37
12.
For systems with water-heated hose:
Pump
setting - Set the flow rate of the heating fluid by
opening the diaphragm pump (ZG) needle valve
(ZP) 45°- 60° open until the pump cycles 60-80
cycles/min (0.7-1.0 gpm or 2.6-3.8 l/min).
13.
For systems with water-heated hose only:
Heater setting - Adjust the heater thermostat to the
desired temperature. The setting at the heater
output thermometer should be approximately 10 °F
(6 °C) higher than the desired paint temperature.
Never exceed the XP system 160 °F (71 °C)
maximum fluid temperature rating. See your Viscon
HP heater manual for instructions.
As a general guideline, heater knob settings are #7
for 105 °F (40 °C), #8 for 135 °F (57 °C), and #8 1/2
for 150 °F (65 °C).
NOTE:
If the hose heat is not being used for more than
one hour, shut off the hot water heater (ZT) and
diaphragm pump (ZG) to lengthen heater life.