Appendix B: Run Screen Details
28
3A3320E
Deviation Active
This is the display screen that appears during an active
deviation. A and B pressure are shown. Refer to the
following table for more information.
Information Screen
The information screen is displayed when an alarm is
active. It shows the active alarm code and the A and B
pressure conditions at the time of the alarm, if
applicable.
To toggle between the Alarm Active screen and the
Alarm Information screen, press:
The red LED will flash when an alarm is present. Refer
to the following table for more information.
NOTE:
To clear the alarm, see
Clear Alarms
, page 15.
Manual Bypass Mode
If the user needs to spray with one of the above errors
active, set the Lower Spray Pressure Limit equal to the
High Pressure Alarm Limit to enter Manual Bypass
Mode. Only use Manual Bypass Mode for emergency
operation. The XP PressureTrak no longer monitors the
pressures and will not shut off the sprayer.
Icon
System Status
Indicates that there is an active deviation.
Icon
System Status
Indicates that there is an active alarm.
The red light on the front LED will be
flashing and the system is disabled.
Alarm Active Code
(see
Error Codes
, page 17).