Setup
3A2776K
29
Prime Heated Fluid Circulation System Continued
Hose Bundle Heating System
1.
Add a 50% water, 50% glycol anti-freeze mix to the
small translucent tank located at the bottom right
corner of the front of the sprayer module.
NOTE:
Even in warm climates, a water/glycol mix
should be used to keep the circulation system clean and
working properly.
2.
With air supply on, adjust the silver knob on top of
the diaphragm pump to start the small black
diaphragm pump under the tank. Adjust pump to
approximately 2-3 cycles per second.
3.
Continue to add the 50/50 fluid mixture as air is
purged from the fluid lines but make sure the tank is
no more than 1/4 to 1/3 full when cold.
NOTE:
Re-tighten all heated fluid circulation tube fittings
after the first time the system has been run at full
temperature.
Double-Walled Tank Heating System
NOTE:
The double-walled tanks are pre-filled with a
water/glycol mix at the factory. If your tanks are already
filled, skip this section.
On all models, there is only one pump and one heater,
which is located on the “A” side feed module.
1.
Add a 50% water, 50% glycol anti-freeze mix to the
small translucent tank located between the tank and
feed pump on the feed module.
2.
Turn the agitator and tank heated fluid pump air ball
valve (CT) ON.
3.
Adjust the silver knob located just above the
. When looking at the Feed
Module Air Controls, the knob will be visible just
above them. See F
. 28. Adjust knob until tank
heated fluid pump reaches approximately 2-3 cycles
per second.
4.
Continue to add the 50/50 fluid mixture as air is
purged from the fluid lines but make sure the tank is
no more than 1/4 to 1/3 full when cold.
NOTE:
Re-tighten all heated fluid circulation tube fittings
after the first time the system has been run at full
temperature.
F
IG
. 27
FEED PUMP
BYPASS
ti20127a
CT
F
IG
. 28
Adjustment Knob Location