Troubleshooting
312666W
31
Leakage between flat tip and mix
chamber.
Tip not seated properly.
Reassemble. See
Damaged/missing o-ring (47).
Replace. See
,
Pressure imbalance.
Plugged impingement ports.
Plugged check valves (44, 45).
Clean. See
Viscosities not equal.
Adjust temperature to
compensate.
Plugged fluid screens.
Clean. See
A and/or B fluid in gun air section. Damaged side seals (42, 43).
Replace. See
Damaged mix chamber (14).
Replace. See
Damaged side seal o-rings (42d,
42e).
Replace. See
Tightened flat tip retainer with
fluid valves (1b) open.
Close valves first.
Fluid mist from mix chamber.
Damaged side seals (42, 43).
Replace. See
Damaged side seal o-rings (42d,
42e).
Replace. See
Damaged mix chamber (14).
Replace. See
Dosed ClearShot Liquid normal.
No action required.
Rapid buildup of material on air
cap.
Plugged front cover holes.
Clean or Replace Front Cover
and Retainer
Damaged/missing fluid housing
o-ring (2b or 2c).
Replace. See
Damaged front o-ring (2b).
Replace. See
Reduced cleanoff air.
Damaged fluid housing o-ring
(2d).
Replace. See
Excessive purge air when fluid
valves are closed and gun is
de-triggered.
Damaged/missing fluid housing
o-ring (2c).
Replace. See
Fluid does not shut off when fluid
valves are closed.
Damaged fluid valves (1b).
Replace. See
Burst of air from muffler when gun
is triggered.
Normal.
No action required.
PROBLEM
CAUSE
SOLUTION