background image

8

307622

Operation

Pressure Relief Procedure

WARNING

INJECTION HAZARD

Fluid under high pressure can be in-
jected through the skin and cause 
serious injury. To reduce the risk of an

injury from injection, splashing fluid, or moving
parts, follow the 

Pressure Relief Procedure

whenever you

D

Are instructed to relieve the pressure

D

Stop spraying/dispensing

D

Check or service any of the system equipment

D

Install or clean the spray tip/nozzle

1.

Lock the gun/valve trigger safety.

2.

Turn off the hydraulic supply line valve (E) first,
then the return line valve (R).

3.

Unlock the gun/valve trigger safety.

4.

Hold a metal part of the gun/valve firmly to a
grounded metal waste container and trigger it to
relieve the fluid pressure.

5.

Lock the trigger safety.

6.

Open the pump drain valve (required in your
system), having a container ready to catch the
drainage.

7.

Leave the drain valve open until you are ready to
spray again.

If you suspect that the spray tip or hose is completely
clogged, or that pressure has not been fully relieved
after following the steps above, very slowly loosen the
hose end coupling and relieve pressure gradually, then
loosen completely. Now clear the tip or hose obstruc-
tion.

Содержание Viscount I 1000

Страница 1: ...STAINLESS STEEL Viscountr I 1000 Pump 1000 psi 6 9 MPa 69 bar Maximum Hydraulic Input Pressure 1000 psi 6 9 MPa 69 bar Maximum Fluid Outlet Pressure Part No 218077 Series B U S Patent No 4 383 475 Pat...

Страница 2: ...for its intended purpose If you are uncertain about usage call your Graco distributor D Do not alter or modify this equipment Use only genuine Graco parts and accessories D Check equipment daily Repai...

Страница 3: ...igger safety operates before spraying D Lock the gun valve trigger safety when you stop spraying D Follow the Pressure Relief Procedure on page 8 whenever you are instructed to relieve pres sure stop...

Страница 4: ...debris including solvent rags and gasoline D Electrically disconnect all equipment in the spray area D Extinguish all open flames or pilot lights in the spray area D Do not smoke in the spray area D...

Страница 5: ...oses Use only electrically conductive hoses D Hydraulic power supply Follow manufacturer s recommendations D Spray gun or dispensing valve Obtain grounding through connection to a properly grounded fl...

Страница 6: ...re 3 4 npt f fluid intake KEY A B C D E F G H J K L M N P Q R Fluid hose to gun Fluid drain valve Suction hose Hydraulic return line Hydraulic supply line shutoff valve Pressure gauge Flow control val...

Страница 7: ...ly line and a minimum 5 8 in ID return line On the hydraulic oil supply line L install a shutoff valve E to isolate the system for servicing a fluid pressure gauge F to monitor hydraulic oil pressure...

Страница 8: ...ydraulic supply line valve E first then the return line valve R 3 Unlock the gun valve trigger safety 4 Hold a metal part of the gun valve firmly to a grounded metal waste container and trigger it to...

Страница 9: ...a grounded metal pail and aimed into it and use the lowest possible pressure to flush See Fig 2 Then follow the Pressure Relief Procedure on page 8 Fig 2 01136 Maintain firm metal to metal contact be...

Страница 10: ...p empties the supply container air is sucked into the pump causing it to run too fast and to be damaged If the pump runs too fast shut it off immediately Fill the supply container and prime the pump t...

Страница 11: ...tion Exhausted fluid supply Refill reprime or flush Held open or worn intake valve or piston packings Clear service Piston check valve needs adjustment Adjust See page 10 Excessive hydraulic fluid sup...

Страница 12: ...s possible Relieve the pressure Stop the pump at the bottom of its stroke 2 Disconnect all hoses from the displacement pump 3 If you remove the pump from its mounting discon nect the hydraulic hoses f...

Страница 13: ...107195 ADAPTER straight thd 37_ flare for 1 2 dia tube 1 9 217221 TUBE inlet 1 2 ID 1 10 107197 TEE run straight thd 3 4 16 UNF 2a 37_ flare m 1 11 104029 CLAMP grounding 1 12 104582 WASHER tab 1 13 1...

Страница 14: ...t Pressure 1000 psi 6 9 MPa 69 bar Maximum Hydraulic Fluid Volume 3 gpm 11 7 liter min Fluid Delivery Rate at 60 cycles min 3 gpm 11 7 liter min Maximum Hydraulic Fluid Temperature 130_ F 54_ C Cycles...

Страница 15: ...28 4 in 721 mm 13 7 in 348 mm 3 4 npt FLUID INLET 1 2 npt FLUID OUTLET 7 8 14 unf 2a 37_ flared m OUTLET ADAPTER 3 4 16 unf 2a 37_ flared m OUTLET ADAPTER 4 1 4 108 mm dia CUTOUT TWO 5 15 8 mm holes...

Страница 16: ...h of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or propert...

Отзывы: