Graco VIBRA-FLO 17P002 Скачать руководство пользователя страница 4

VIBRA-FLO Shaker Adjustment 

4

3A4696B

VIBRA-FLO Shaker Adjustment

The VIBRA-FLO shaker is shipped preset for
the best performance. The speed is adjusted
by adjusting the VIBRA-FLO knob on the
control.

1.

Turn VIBRA-FLO shaker ON/OFF 
switch to the ON position.

2.

Turn VIBRA-FLO knob to maximum.

3.

If the VIBRA-FLO shaker is making 
excessive noise turn the VIBRA-FLO 
knob to a lower setting. Depending upon 
the supply voltage the shaker may not 
operate if the VIBRA-FLO is set too low.

4.

If the armature and coil needs 
adjustment, use a feeler gauge to adjust 
shaker gap. Set gap to 0.042 – 0.052 
inch (1.06 – 1.32 mm).

1

2

3

4

5

ti30652a

ti30206a

ti30151a

ti30152a

ti30153a

ti30154a

ti30155a

Содержание VIBRA-FLO 17P002

Страница 1: ...se in explosive atmosphere or hazardous locations Models 17P002 17P196 Important Safety Instructions Read all warnings and instructions in this manual and related manuals Be familiar with the controls and the proper usage of the equipment Save these instructions ti30745a www graco com techsupport ...

Страница 2: ...lectric shock When repair or replacement of the cord or plug is required do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire Check with a qualified electrician or serviceman when the grounding instructions are not completely understood or when in doubt as to whether the p...

Страница 3: ...void agency approvals and create safety hazards Make sure all equipment is rated and approved for the environment in which you are using it ELECTRIC SHOCK HAZARD This equipment must be grounded Improper grounding setup or usage of the system can cause electric shock Turn off and disconnect power cord before servicing equipment Connect only to grounded electrical outlets Use only 3 wire extension c...

Страница 4: ... to the ON position 2 Turn VIBRA FLO knob to maximum 3 If the VIBRA FLO shaker is making excessive noise turn the VIBRA FLO knob to a lower setting Depending upon the supply voltage the shaker may not operate if the VIBRA FLO is set too low 4 If the armature and coil needs adjustment use a feeler gauge to adjust shaker gap Set gap to 0 042 0 052 inch 1 06 1 32 mm 1 2 3 4 5 ti30652a ti30206a ti3015...

Страница 5: ...Notes 3A4696B 5 Notes ...

Страница 6: ...4696B VIBRA FLO Texture Hopper Parts 1 19 36 37 34 35 17a 4 7 2 3 5 6 10 12 11 17 16 15 14 9 41 ti30209a 8 137 12c 12b 12a 26 11 7 3 Ref Torque Ref Torque 30 40 in lb 3 4 4 5 N m 45 50 in lb 5 1 5 7 N m 170 190 in lb 19 2 21 5 N m 3 11 7 ...

Страница 7: ...b 242001 CORDSET adapter CEE 7 7 Europe 1 12c 128206 CORDSET CEE 7 7 Europe Schuko Model 17P196 1 14 156306 WASHER flat 2 15 116038 WASHER wave spring 2 16 15E891 CLIP retaining 2 17 119420 WHEEL pneumatic 2 17a 253132 KIT repair tube 1 19 112958 NUT hex flanged 4 20 246331 HOSE drain includes 21 1 21 241920 DEFLECTOR threaded 1 22 116756 FITTING elbow 45 1 26 116281 CORD power Model 17P002 1 30 1...

Страница 8: ...0 in lb 9 0 11 2 N m 1 2 Ref Part Description Qty 1 17N610 PLATE shaker 1 2 17N607 BRACKET mounting armature 1 3 17R135 COIL electromagnetic 230V 1 4 17N606 BLOCK armature 1 5 111800 SCREW cap HH 2 6 113161 SCREW flange HH 7 7 110755 WASHER flat 3 8 17P261 CLAMP loop cushioned 3 9 100527 WASHER flat 2 11 17P658 GUARD shaker 1 12 17R136 CORD control shaker 1 13 17P396 LABEL branding shaker 1 Ref Pa...

Страница 9: ... ENCLOSURE control 1 2 260067 FITTING strain relief 1 2 NPT 1 3 17S020 BOARD control shaker 1 4 17R471 INSULATOR box 1 5 195429 SWITCH toggle 1 6 117625 NUT locking 1 7 17S079 FILTER power line 1 8 195428 BOOT toggle 1 9 17J017 LABEL 1 10 116167 KNOB potentiometer 1 11 114391 SCREW grounding 2 12 17R347 LABEL control shaker 1 13 119775 NUT panel 1 14 17P082 JUMPER brown not shown see page 10 1 15 ...

Страница 10: ...5 ENCLOSURE GROUND SCREWS NUT 2X CONTROL BOARD 3 POTENTIOMETER JUMPER WIRE 14 JUMPER WIRE JUNCTION BOX SUB ASSEMBLY FROM SHAKER COIL FROM POWER CORD STRAIN RELIEF 1X SHAKER CONTROL WIRING DIAGRAM BROWN LINE IN LOAD BROWN BROWN BLUE GREEN GREEN BLUE ti30747a ...

Страница 11: ...ironmental temperature range 40 120 F 4 49 C Minimum fluid temperature 40 F 4 C Dimensions Height 42 in 106 7 cm Length 31 5 in 80 0 cm Width 22 5 in 57 2 cm Weight 54 lb 24 5 kg Noise Sound Power 84 dBa Sound Pressure 71 dBa Notes Sound pressure measured 3 feet 1 meter from equipment Sound power measured per ISO 3744 ...

Страница 12: ...polis International Offices Belgium China Japan Korea GRACO INC AND SUBSIDIARIES P O BOX 1441 MINNEAPOLIS MN 55440 1441 USA Copyright 2017 Graco Inc All Graco manufacturing locations are registered to ISO 9001 www graco com Revision B April 2017 Graco Information For the latest information about Graco products visit www graco com For patent information see www graco com patents TO PLACE AN ORDER c...