SPRAYING

All information, illustrations, and specifications in this document are based on the latest product information 

 available at the time of publication. The right is reserved to make changes at any time without notice.

Point gun at area to be sprayed about 30 cm from surface, and begin moving gun before triggering. 

A good spray pattern is evenly distributed as it hits surface. Set pressure just high enough to spray without 

heavy edges. Use smaller tip size for thinner material and a larger tip size for thicker material if pressure 

adjustment cannot achieve even spray pattern.

Trigger gun

until pressure

is relieved.

Turn prime valve down 

to DRAIN position 

and then over 

to FAST FLUSH

Trigger gun into waste pail

Keep gun triggered and 

turn pressure knob 

to use FAST FLUSH

until water coming 

out of gun is clean.

Wipe outside of sprayer, hose 

and gun with rag soaked 

in water or mineral spirits.

Turn prime valve
to Prime position 

(down).

Turn prime valve down to stop 

FAST FLUSH, keep the pump running til 

clear water comes out the drain tube. 

Turn pressure 

control knob to lowest setting.

Remove filters from gun and sprayer, if 

installed.

Clean and inspect filter, assemble gun 

and filter house, without filter.

Check inlet strainer for 

clogs and debris

Increase pressure

until sprayer starts.

As soon as Pump Armor

comes out of drain tube,

set power switch to OFF.

Set power

switch to OFF.

Turn safety lever of gun to OFF.

Turn pressure control knob

to lowest setting, 

set power switch to ON

Place drain tube in waste pail 

Place drain tube in waste 

pail and siphon tube in

container of 

Pump Armor™

Place suction tube in appropriate 

cleaning fluid

Remove tip guard

Screw inlet screen onto

siphon tube, replace

manifold filter and spacer,

and assemble gun with

filter, tip and guard.

WASTE

WASTE

Fill throat packing nut

with TSL™