Troubleshooting
22
3A1204E
Spray Pattern Diagnostics
Sprays with poor results
Tip is partially clogged
See
Unclogging Tip/Guard Assembly
, page
13.
Tip is not in correct position
Rotate tip to SPRAY position.
Incorrect tip for application of
material.
See
Reversible Tip Selection Chart,
page
11.
Tip filter is partially clogged
Clean or replace filter. See page 13.
Suction Tube screen is partially clogged.
Clean or replace Suction Tube. See page 14.
Fine Finish Optimizer is partially clogged.
Clean or replace Fine Finish Optimizer. See
page 9.
Fine Finish Optimizer is installed while using
an incompatible material.
Make sure compatible material is being used.
See
Reversible Tip Selection Chart
, page
11.
Tip is worn or damaged
Replace tip. See
Install Tip/Guard Assembly
,
page 11.
Inlet or Outlet Valves are worn.
See
Repair Kit
, page 18.
Paint leaks from sprayer trigger
area.
Sprayer has reached its maximum life.
Replace sprayer.
Battery is discharged but char-
ger still displays green light
when battery is inserted.
Damaged battery.
Replace battery.
Problem
Cause
Solution
Problem
Cause
Solution
Spray pattern is pulsating:
Fine Finish Optimizer is installed while using
an incompatible material.
Operator is moving too fast while spraying.
Make sure material is compatible. See
Revers-
ible Tip Selection Chart
, page 11.
Slow speed of movement.
Spray pattern has tails:
Fine Finish Optimizer is installed while using
an incompatible material.
Fine Finish Optimizer is partially clogged.
Material not compatible with sprayer.
Inlet or Outlet Valves are worn.
Make sure compatible material is being used.
See
Reversible Tip Selection Chart
, page 11.
Clean or replace Fine Finish Optimizer.
See page 9.
Switch material.
See
Repair Kit
, page 18.
Spray pattern has dripping:
Sprayer is moving too slow for material.
Sprayer is too close to target surface.
Holding trigger while changing spray
direction.
Incorrect tip for application of
material.
Tip is worn or damaged.
Move sprayer faster while spraying.
Move sprayer away from surface (10 in).
Release trigger when changing directions.
See
Reversible Tip Selection Chart,
page 11.
Replace tip. See
Install Tip/Guard Assembly
,
page 11.
ti15524
ti15526
ti15522
Содержание TrueCoat Pro-X 258850