Wet
Wet
Wet Out
Out
Out the
the
the System
System
System
NOTICE
NOTICE
NOTICE
To prevent material curing in system, never load
mortar or epoxy into a dry system. Loading mortar
or epoxy into a dry system will cause the material
to stick to internal components and cure causing
damage and requiring replacement of those parts.
Always wet out the system by circulating clean
fluid through the applicator back into the hopper
before loading any mixed mortar. This is normally
done with the flushing fluid, but sometimes resin
or commercially available concrete pump priming
fluids are used depending on what material is being
sprayed.
• Use the material flushing agent recommended on
the material application data sheet.
• When finished, pump out the excess fluid. Then
drain out remaining fluid by loosening the bottom
cam fitting.
1.
Close the bleed type master air valve (B).
B
A
ti21575a
Figure 11
2.
Remove tip from applicator.
3.
Partially fill the clean hopper with material
flushing agent, depending on the material you
will be spraying.
4.
Turn air regulator adjustment knob (F)
counterclockwise until it stops and gauge (E)
reads zero.
E
F
ti21571a
Figure 12
5.
Verify zero cavity relief valve (J) is closed.
6.
Place applicator outlet in grounded pail.
7.
Open the fluid ball valve (V) on the applicator.
ti21663a
Figure 13