Operation
3A6393D
19
Hopper Removal
The hopper assembly allows easy detachment of the
hopper from the pump. To remove the hopper from the
pump, perform the following steps:
1. Follow the
on page 18.
2. Open the over-center latch (K) to loosen the clamp
between the hopper elbow and the lower.
3. Remove the locking pin and pull down the hopper
latch (U) on the hopper plate.
NOTE:
If needed, push down on the hopper elbow
to completely disengage from the pump lower.
4. Remove the two hopper pins (P) from the front legs
of the cart.
5. Lift up on the handle and pull the hopper (J) away
from the sprayer.
NOTE:
If the hopper elbow needs to be thoroughly
cleaned, rotate the second knob (K) to loosen the clamp
between the elbow and the hopper. Remove and clean
the elbow.
NOTE:
To re-install the hopper, follow the steps above
in reverse order.
Shutdown
1. To shutdown, follow the
procedure on page
12.
2. Turn the motor power switch (S) to OFF.
Lifting Instructions
When lifting the unit, only lift at the points indicated by
the arrows shown in the illustration.
To help prevent injury from suction, never place
hands near the pump fluid inlet when pump is
operating or when hopper is removed.
WLD
.
8
3
J
WLD
-
3
To avoid injury from splashing fluid, never open a
cam-lock hose or applicator fitting while there is
pressure in the fluid line.
NOTICE
To prevent rust, never leave water or water-based fluid
in the pump overnight.
WLD