Operation
14
3A6393D
Prime with Material
The applicator nozzle or tip must be removed during
priming. Always push out any remaining water into a
waste container before circulating material. Always
circulate clean material back into the hopper for a few
minutes before beginning to spray.
1. Follow the
2. Turn the flow adjustment knob (H) counterclockwise
until it stops.
3. Remove tip from applicator.
4. Fill the clean hopper with material to be sprayed.
5. Place hose outlet in a 5 gallon waste container.
6. Turn the motor power switch (S) to ON.
7. Turn the flow adjustment knob (H) clockwise slowly
to increase pressure, until water is purged out and a
steady stream of material flows from applicator.
8. To stop dispensing, turn adjustment knob
counterclockwise until it stops.
9. Place the hose outlet into the hopper.
10. Recirculate a few gallons of material to be sure the
material is flowing properly.
11. Turn the flow adjustment knob (H) counterclockwise
to stop the pump.
12. Install the applicator without a tip onto the hose and
pump material until material has been pushed out of
the applicator, then stop the pump.
13. Install a tip onto applicator (see your applicator
manual). The system is now primed and ready to
spray.
NOTICE
To prevent material curing in system, never load
material into a dry system. Loading material into a dry
system will cause the material to stick to internal
components and cure, causing damage and requiring
replacement of those parts.
NOTICE
To prevent damage to pump seals caused by
cavitation, run the pump slowly until the system is
primed.