Maintenance
28
309298J
Check for Fluid Leakage
During operation, periodically check the manifold
exhaust tube (YY) and both ends of the gun shroud (ZZ)
for the presence of fluid. See F
IG
. 18.. Fluid in these
areas indicates leakage into the shroud, which could be
caused by leaks at the fluid tube connections or fluid
packing leakage.
If fluid is seen in these areas, stop spraying immediately.
Relieve the pressure, then remove the gun for repair.
Fig. 18. Check for Fluid Leakage
WARNING
Fire and Explosion Hazard
If any fluid leakage from the gun is
detected, stop spraying immediately. Fluid
leakage into the gun shroud could cause
fire or explosion and result in serious injury
and property damage.
WARNING
Skin Injection Hazard
To reduce the risk of a fluid injection injury,
always follow the Pressure Relief Proce-
dure on page 18 when you stop spraying
and whenever you are instructed to relieve
the pressure.
TI1736A
TI1716A
YY
YY
ZZ
ZZ
Содержание TI1713A
Страница 54: ...Accessories 54 309298J ...