Appendix B - Data Exchange Interface
18
3A5186B
Data Exchange Interface Pointer Designation Tabl
Pointer
Designa
tion
Description
Comments
Read/
Write
0
Interface Not Active
1
Set Temperature Units
Value - Setting
0 - °F
1 - °C
Read
2
Read Temperature Units
Write
3
Set Mass Units
Value - Setting (0 - g, 1 - kg, 2 - lb)
Write
4
Read Mass Units
Read
5
Set Specific Gravity
Specific gravity in thousandths (for instance a SG setting of
1.055 = 1055).
Write
6
Read Specific Gravity
Read
7
Set High Temp. Alarm Offset
In whole selected C or F units of measure.
Write
8
Get High Temp. Alarm Offset
Read
9
Set High Temp. Deviation Offset
Write
10
Get High Temp. Deviation Offset
Read
11
Set Low Temp. Alarm Offset
Write
12
Get Low Temp. Alarm Offset
Read
13
Set Low Temp. Deviation Offset
Write
14
Get Low Temp. Deviation Offset
Read
15
Set Prime Pump Duration
Prime pump duration setting in second increments
Write
16
Get Prime Pump Duration
Read
17
Read System Version
A 32-bit string in the format of 0xXXCCBBAA.
0xCC…Build Version
0xBB…Minor Version
0xAA…Major Version
Read
18
Read System Date
A 32-bit string in the format of 0xXXDDCCBB.
0xDD…Year (0x0D corresponds to 2013)
0xCC…Month (0x0A corresponds to October)
0xBB…Day
Read
19
Read System Time
A 32-bit string in the format of 0xDDHHMMSS.
0xHH…Hours
0xMM…Minutes
0xSS…Seconds
0xDD...Day of week (0x01 corresponds to Monday)
Read
20
Read ADM Version
A 32-bit string in the format of 0xXXMMNNBB
0xMM...Major #
0xNN...Minor #
0xBB...Build #
21 - 90 Reserved for Future Use