12
12
12 Zone
Zone
Zone Upgrade
Upgrade
Upgrade Kit
Kit
Kit Installation
Installation
Installation
1.
Disconnect plug from power outlet or turn off
circuit breaker for incoming power.
2.
Place grounding wrist strap (7) over your wrist
and secure other end to a grounded surface.
3.
Set the kit’s MZLP (1) rotary switch to “3” on a
primary system or “7” on a secondary system.
4.
Remove screws (B), remove plate (A), and
gasket (C) from system. Use screws (2) to install
MZLP (1) onto system as shown.
Note
The new MZLP (1) will be referred to as
MZLP 3, and the other two that came
with the system will be referred to as
MZLP 1 and MZLP 2.
5.
Open the electrical enclosure door.
Note
Do not force the electrical connection.
Minimal force is required to seat the
connector. If resistance is felt, stop, and
verify the connector orientation.
6.
Connect cable (4) to J3 connector on MZLP 2
and J6 connector on MZLP (1). Remove existing
power cable from MZLP 2 J2 and AWB J5
connector.
7.
Connect power harness (6) to MZLP 2 and MZLP
3 J2 connector and J5 connector on AWB. Install
8.
See
, to connect a
heated hose or fluid control device.
9.
To ensure your system has the latest
software, insert token (8) into the ADM. See
.
334130D
95
Содержание Therm-O-Flow 200
Страница 48: ...Repair Figure 28 48 334130D...
Страница 56: ...Repair Figure 34 Inside of Electrical Control Enclosure 56 334130D...
Страница 59: ...Electrical Schematics 400V 400V 400V 3 3 3 Phase 50 Phase 50 Phase 50 Hz Hz Hz 334130D 59...
Страница 60: ...Electrical Schematics 400 600VV 400 600VV 400 600VV 3 3 3 Phase 60 Phase 60 Phase 60 Hz Hz Hz 60 334130D...
Страница 61: ...Electrical Schematics AWB AWB AWB and and and MZLP 1 MZLP 1 MZLP 1 334130D 61...
Страница 63: ...Electrical Schematics MZLP MZLP MZLP Zones Zones Zones 334130D 63...
Страница 67: ...Parts Electrical Electrical Electrical Module Module Module 334130D 67...
Страница 68: ...Parts 68 334130D...
Страница 94: ...Accessories and Kits 94 334130D...