Replace
Replace
Replace Pump
Pump
Pump RTD
RTD
RTD
1.
Turn the main power switch off.
2.
Remove the screws that hold the front shroud in
place and remove front shroud.
3.
If sensor wire is connected to electrical enclosure,
disconnect it.
4.
Loosen the clamp (321) holding sensor on pump.
5.
Tie the leads of the new sensor (320) to the old
sensor and remove the old sensor. The leads of
the new sensor will be easily drawn through the
conduit for reconnecting.
6.
Replace the sensor (320) in clamp (321):
a.
Place sensor approximately 30° counter
clock-wise from pump outlet.
b.
Tighten clamp (321).
7.
Re-connect sensor wire to electrical enclosure.
Replace
Replace
Replace MZLP
MZLP
MZLP Fuse
Fuse
Fuse
Each MZLP module comes with the following fuses:
J
1
J 2
J 3
J 6
J 5
J 7
F10 F9
F8 F7
F6
F5
F4 F3
F2
F1
Figure 30 Fuse Locations
Fuse
Fuse
Fuse Kit
Kit
Kit Fuse
Fuse
Fuse
Part
Part
Part
F1, F2
250VAC, 25A, long, white
ceramic
24V289
F3-F10 250VAC, 8A, fast acting, clear
glass
Spare fuse kit included with system.
NOTICE
NOTICE
NOTICE
To prevent system damage, always use fast
acting fuses. Fast acting fuses are required for
short-circuit protection.
1.
Turn the main power switch off.
2.
Open electrical enclosure door.
3.
Use a proper non-conductive fuse puller tool to
remove the blown fuse.
NOTICE
NOTICE
NOTICE
Using an improper tool, such as screw drivers
or pliers, may break glass on fuse.
Note
F1 and F2 are white ceramic and indicate
25A on the barrel.
Note
F3-F10 are clear glass and indicate 8A
on the barrel.
4.
Use a proper non-conductive fuse puller tool to
install the new fuse
NOTICE
NOTICE
NOTICE
Using an improper tool, such as screw drivers
or pliers, may break glass on fuse.
5.
Close electrical enclosure.
50
334130D
Содержание Therm-O-Flow 200
Страница 48: ...Repair Figure 28 48 334130D...
Страница 56: ...Repair Figure 34 Inside of Electrical Control Enclosure 56 334130D...
Страница 59: ...Electrical Schematics 400V 400V 400V 3 3 3 Phase 50 Phase 50 Phase 50 Hz Hz Hz 334130D 59...
Страница 60: ...Electrical Schematics 400 600VV 400 600VV 400 600VV 3 3 3 Phase 60 Phase 60 Phase 60 Hz Hz Hz 60 334130D...
Страница 61: ...Electrical Schematics AWB AWB AWB and and and MZLP 1 MZLP 1 MZLP 1 334130D 61...
Страница 63: ...Electrical Schematics MZLP MZLP MZLP Zones Zones Zones 334130D 63...
Страница 67: ...Parts Electrical Electrical Electrical Module Module Module 334130D 67...
Страница 68: ...Parts 68 334130D...
Страница 94: ...Accessories and Kits 94 334130D...