Roller Replacement
309586R
9
Roller Replacement
Use Roller Repair Kit 234214.
Disassembly
1.
Relieve Pressure
, page 5.
2.
Unplug sprayer from outlet
3.
Remove shroud (6 bolts).
4.
Remove RotoFlex Pump, page 6.
5.
Using a crow bar
as a wedge to
keep rollers from
moving, loosen
shoulder bolt.
6.
Remove rollers.
Reassembly
1.
Replace rollers.
2.
Using a crow bar as a wedge to keep rollers from
moving, torque bolts to 40 ft. lbs.
3.
Reinstall RotoFlex Pump hose on plate, page 6.
4.
Replace shroud. Tighten bolts (6).