![Graco T-MAX 506 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/graco/t-max-506/t-max-506_operation-repair-parts_2251808025.webp)
Start Up - Airless
3A6748B
25
e.
Once a steady stream flows from
the material hose, run for an
additional 30 seconds.
f.
Turn ON/OFF Switch to OFF.
4.
Install filter or air passage plug and tip
extension. Material consistency and tip
size will determine which filter size to
use. In certain instances, air passage
plug with no screen is needed with large
tips to successfully spray materials with
sand or rock.
5.
Connect applicator to material hose.
6.
Turn ON/OFF Switch to ON.
7.
Turn applicator ON. Turn Pressure
Control Knob clockwise until desired
material delivery rate is achieved. Run
for 15 seconds.
ti11697a
ti8794a
Содержание T-MAX 506
Страница 53: ...Repair 3A6748B 53 6 Install motor cover using four screws 7 Connect pump to hopper ...
Страница 63: ...Repair 3A6748B 63 Cross Section Reference Pump Ball Identification 6912 ...
Страница 67: ...Notes 3A6748B 67 Notes ...
Страница 68: ...Parts Hopper Frame 68 3A6748B Parts Hopper Frame b a ...
Страница 70: ...Parts Power Module 506 657 70 3A6748B Parts Power Module 506 657 PAGE 78 PAGES 74 75 ...
Страница 72: ...Parts Power Module 6912 72 3A6748B Parts Power Module 6912 PAGE 80 PAGE 76 ...
Страница 76: ...Parts Pump 25E668 6912 76 3A6748B Parts Pump 25E668 6912 ...
Страница 78: ...Parts Control Box 506 657 78 3A6748B Parts Control Box 506 657 ...
Страница 81: ...Wiring Diagrams 3A6748B 81 Wiring Diagrams 506 657 ...
Страница 82: ...Wiring Diagrams 82 3A6748B 6912 US ...
Страница 83: ...Wiring Diagrams 3A6748B 83 6912 UK ...