Coalescer with Automatic Drain 

2

310611G

Coalescer with Automatic Drain

(Part No. 22605, Series B)

Installation

It is always recommended that a Sharpe air filter be 
installed upstream of the coalescing filter to remove 
0.01 micron and larger size particles and separate large 
droplets of moisture from the air line.

Maintenance

To maintain maximum filtering efficiency and to avoid 
excessive pressure drop, the filter must be kept clean. 
Bowl drainage is automatic with the float drain. Remove 
the bowl to drain manually. A visible coating of dirt on 
the filter element surface or an excessive pressure drop 
is an indication that cleaning is necessary.

Cleaning

To clean, it is not necessary to remove the complete fil-
ter from the line. Disassembly is simple and does not 
require tools. Before disassembly, shut off the air supply 
and depressurize coalescer. Clean all parts with clean-
ing solvent and blow out body before reassembly. 
Replace coalescing element (part no. 16W407).

Pressure Drop Indicator

The differential pressure drop indicator on this unit is 
designed to provide early detection of a clogged 
coalescing filter element. As the filter element becomes 
clogged the red indicator will start to rise while air is 
flowing through the unit. When the pressure drop across 
the element reaches 10-12 psi (.07-.08 MPa, 0.7-0.8 
bar) the red indicator will be in full view and the element 
should be replaced. Failure to replace the element when 
the pressure drop exceeds 10 psi (.07 MPa, 0.7 bar) will 
affect your air quality and tool efficiency.

Specifications

Air Inlet 1/2 in. F.P.T.
Air Outlet 1/2 in. F.P.T.
Air Flow Capacity 50 cfm (2 m

3

/min.) at 100 psi 

(0.7 MPa, 7 bar)

Max. Operating Pressure 175 psi (1.2 MPa, 12 bar)
Max. Temperature 150°F (65°C)

Parts (Series B)

Part No.

Description

24U115

Automatic Drain

24U117

Mounting Bracket Kit

127289

O-Ring

24U116

Pop-up Indicator Repair Kit

16W407

0.01 Micron Coalescer Element

16W811

Baffle End Cap

O-Ring

Coalescer

Automatic
Drain

(127289)

(24U115)

Element
(16W407)

Pop-up
Indicator
(24U116)

Baffle
End Cap
16W811

Mounting
Bracket Kit
(24U117)

ti22165a