Repair
3A8626C
27
21. Tighten the bolt (18) (torque 25 - 35 ft-lb/33.9 - 47.5
N•m).
22. Align the guide arm (29) and guide arm (30), then
install screws (27) and tighten (torque 20 - 30
ft-lb/27.1 - 40.7 N•m).
23. Align the pedestal assembly (26) to the base (24).
Install two screws (27) and tighten (torque 20 - 30
ft-lb/27.1 - 40.7 N•m).
24. Re-install the reel to the ceiling or wall.
25. Install the hose onto the spool following the
instructions, page 18.
26. Flush the hose following
page 9.
27. Set the spring tension following
, page 20.
Replace the Hose
1. Follow the
2. Fully extend the hose (B) and latch the reel (F
. 24).
3. Attach a C-clamp (A) to the reel flange to prevent
the reel from unintentionally becoming unlatched
and spinning freely (F
4. Remove the hose stop from the hose end and put
all of the parts in a secure place for re-installation
on the new hose (F
. 25).
a. Loosen and remove screws and nuts (F
b. Separate the two hose stop components to
remove from the end of the hose (F
SPRING TENSION HAZARD
The hose reel spring is always under great tension,
which if released in an uncontrolled manner could
cause serious injury.
• Never allow the reel to spin freely. Uncontrolled
spinning could cause serious injury if hit by the
hose.
• Securely fasten the reel in place while making
adjustments.
• The hose reel spring is not a serviceable part, Do
not attempt to replace or service the hose reel
spring.
• Always wear heavy gloves while adjusting the
spring tension to protect your hands from being
cut on the hose reel.
F
IG
. 24
A
B