background image

Usage

Usage

This pump must b e used as part of a SaniForce drum

or tote unloader system. Refer to the appropriate

system manuals for operation instructions of this

pump when installed in those systems.

Cleaning Preparation

WARNING

PRESSURIZED FLUID HAZARD
This equipment stays pressurized until pressure

is relieved manually. To help prevent serious

injury from moving parts, or from pressurized fluid,

such as skin injection, splashing in the eyes or on

skin, follow the Pressure Relief Procedure in your

system manual when you stop pumping and before

you clean, check, or service the equipment.
PERSONAL PROTECTIVE EQUIPMENT
Wear appropriate protective equipment when

in the work area to help prevent serious injury,

including eye injury, hearing loss, or inhalation of

toxic fumes.

This procedure involves thoroughly disassembling

and cleaning the individual parts in the pump lower.

Prior to performing these procedures:
1. Flush the pump and relieve pressure as

described in the system manuals.

2. Disconnect all hoses.
3. Remove the pump from the system.
Notes:
• Be sure to follow your national and state sanitary

standard codes and local regulations.

• Use appropriate cleaning and disinfecting agents,

at intervals appropriate for product processed.

• Follow cleaning product manufacturer’s

instructions.

Cleaning the Air Motor

1. Perform

Cleaning Preparation, page 3

.

2. Remove air motor air supply and exhaust fittings

(14, 32).

3. Loosen the hand screw (18) and remove the

upper shield (9).

4. Clean thoroughly the surface between the upper

and lower shields. Replace upper shield, hand

nut, and air fittings.

5. Reassemble the air motor
6. Clean the pump lower. See

Priming Piston Service, page 4

.

3A5798B

3

Содержание SaniForce 5:1

Страница 1: ...e unloader systems For professional use only Important Safety Instructions Read all warnings and instructions in this manual and in related system manuals Save all instructions Maximum Working Air Pre...

Страница 2: ...ment Pump Model 25N005 13 Double Ball Displacement Pump Model 25N006 15 Product Dimensions 17 Performance chart 18 Technical Data 19 Graco Standard Warranty 20 Models Pump Model Pump Lower Replacement...

Страница 3: ...aring loss or inhalation of toxic fumes This procedure involves thoroughly disassembling and cleaning the individual parts in the pump lower Prior to performing these procedures 1 Flush the pump and r...

Страница 4: ...ressure as described in the system manuals disconnect all hoses and remove the pump from the system 1 Perform Cleaning Preparation page 3 2 Loosen the coupling nut 6 and lower far enough to remove the...

Страница 5: ...of the sanitizer one by one as needed 5 Install the v block packing 113 and bearing 112 in the packing housing 114 The lips of the packing must face down into the housing and the lip of the bearing mu...

Страница 6: ...ent when in the work area to help prevent serious injury including eye injury hearing loss or inhalation of toxic fumes This procedure involves thoroughly disassembling and cleaning the individual par...

Страница 7: ...the cylinder 101 Disassemble the valve Clean and inspect the parts 2 Push the displacement rod 103 out through the bottom of the cylinder 101 Remove the piston housing 104 by removing the retaining pi...

Страница 8: ...e housing and the lip of the bearing must face up Install the o ring 110 on the outside of the housing Place the packing housing in the top of the cylinder 6 Install the o rings 109 110 on the piston...

Страница 9: ...eads 2 Hand tighten only 3 Apply sanitary lubricant to ease assembly 4 Apply medium strength blue thread locker 5 Apply an appropriate medium strength thread locker on the nut 18 every time it is inst...

Страница 10: ...des grommets Ref 27 1 10 16E029 SHIELD lower includes fasteners Ref 8 and grommets Ref 21 1 11 118134 SCREW cap M8 x 1 25 sst 4 13 16G085 FITTING air inlet 1 2 npt includes Ref 23 1 14 16C946 FITTING...

Страница 11: ...2 Hand tighten only 3 Apply sanitary lubricant to ease assembly 4 Apply medium strength blue thread locker 5 Apply an appropriate medium strength thread locker on the nut 18 every time it is installed...

Страница 12: ...11 118134 SCREW cap M8 x 1 25 sst 4 13 16G085 FITTING air inlet 1 2 npt 1 14 16C946 FITTING 3 4 npt 1 15 512607 CLAMP 1 16 512606 GASKET 1 17 165053 O RING 1 18 16C306 NUT 1 26 17W547 LABEL warning no...

Страница 13: ...Piston Displacement Pump Model 25N005 Priming Piston Displacement Pump Model 25N005 1 Apply appropriate waterproof sanitary lubricant 2 Throat U cup lips must face down 3 Bearing lip must face up 3A5...

Страница 14: ...07 512603 BALL 1 1 2 in 1 108 624243 RING piston 1 109 512602 O RING 1 110 512589 PACKING 2 111 624242 GLAND piston 1 112 624247 BEARING throat 1 113 512605 PACKING 1 114 624246 HOUSING throat 1 115 5...

Страница 15: ...le Ball Displacement Pump Model 25N006 Double Ball Displacement Pump Model 25N006 1 Apply appropriate waterproof sanitary lubricant 2 Throat U cup lips must face down 3 Bearing lip must face up 3A5798...

Страница 16: ...06 624244 PIN ball stop 1 107 512603 BALL 1 1 2 in 1 108 624243 RING piston 1 109 512602 O RING 1 110 512589 PACKING 3 111 624242 GLAND piston 1 112 624247 BEARING throat 1 113 512605 PACKING 1 114 62...

Страница 17: ...1 25N010 25N010C31 Model A in cm B in cm C in cm D in cm 25N009 25N009C31 55 0 139 7 31 5 80 0 26 3 66 8 6 5 16 5 25N010 25N010C31 46 5 118 1 23 0 58 4 17 6 44 7 6 5 16 5 Add 2 5 in 6 3 cm to allow fo...

Страница 18: ...30 3 10 37 8 12 45 4 14 53 0 0 8 17 25 34 42 51 60 0 10 0 28 20 0 57 30 0 85 40 1 13 50 1 42 60 1 70 70 1 98 80 2 27 CYCLES PER MINUTE FLUID FLOW GPM LPM TESTED IN NO 10 WEIGHT OIL FLUID OUTLET PRESS...

Страница 19: ...r 120 F 49 C Air Inlet 1 2 npt f Air Exhaust 3 4 npt m Fluid Inlet Type Priming Piston pumps 3 4 in 8 6 cm Priming Piston with ange for 6 in 15 2 cm Clamp Double Ball pumps ange for 6 in 15 2 cm Clamp...

Страница 20: ...s for lost pro ts lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the d...

Отзывы: