Warnings

WARNING

EQUIPMENT

EQUIPMENT

EQUIPMENT MISUSE

MISUSE

MISUSE HAZARD

HAZARD

HAZARD

Misuse can cause death or serious injury.

• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated

system component. See Technical

Technical

Technical Data

Data

Data in all equipment manuals.

• Use fluids and solvents that are compatible with equipment wetted parts. See Technical

Technical

Technical Data

Data

Data

in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete
information about your material, request Safety Data Sheet (SDS) from distributor or retailer.

• Turn off all equipment and follow the Pressure

Pressure

Pressure Relief

Relief

Relief Procedure

Procedure

Procedure when equipment is not in use.

• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine

manufacturer’s replacement parts only.

• Do not alter or modify equipment. Alterations or modifications may void agency approvals

and create safety hazards.

• Make sure all equipment is rated and approved for the environment in which you are using it.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.

TOXIC

TOXIC

TOXIC FLUID

FLUID

FLUID OR

OR

OR FUMES

FUMES

FUMES HAZARD

HAZARD

HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin,
inhaled, or swallowed.

• Read Safety Data Sheets (SDSs) to know the specific hazards of the fluids you are using.

• Store hazardous fluid in approved containers, and dispose of it according to applicable

guidelines.

SPLATTER

SPLATTER

SPLATTER HAZARD

HAZARD

HAZARD

Hot or toxic fluid can cause serious injury if splashed in the eyes or on skin. During blow off of
platen, splatter may occur.

• Use minimum air pressure when removing platen from container.

PERSONAL

PERSONAL

PERSONAL PROTECTIVE

PROTECTIVE

PROTECTIVE EQUIPMENT

EQUIPMENT

EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury,
including eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment
includes but is not limited to:

• Protective eyewear, and hearing protection.
• Respirators, protective clothing, and gloves as recommended by the fluid and solvent

manufacturer.

3A5404F

5

Содержание SaniForce 3A5402

Страница 1: ...explosive explosive explosive atmospheres atmospheres atmospheres or or or hazardous hazardous hazardous locations locations locations See See See Configuration Configuration Configuration Matrix Matr...

Страница 2: ...mps Instructions and Parts 3A5564 SaniForce 6 1 Sanitary Pumps Instructions and Parts 3A5799 SaniForce 12 1 Sanitary Pumps Instructions and Parts 3A5999 SaniForce High Sanitation Diaphragm Pumps Opera...

Страница 3: ...ON EXPLOSION HAZARD HAZARD HAZARD Flammable fumes such as solvent and paint fumes in work work work area area area can ignite or explode Paint or solvent flowing through the equipment can cause static...

Страница 4: ...dispensing device hose leaks or ruptured components will pierce skin This may look like just a cut but it is a serious injury that can result in amputation Get Get Get immediate immediate immediate s...

Страница 5: ...only for its intended purpose Call your distributor for information Route hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses...

Страница 6: ...e Frame Frame Pump Pump Pump Ram Ram Ram Plate Plate Plate Seal Seal Seal Style Style Style SDU SDU SDU A A A Stainless Steel 01 01 01 5 1 Double Ball A A A 20 Inflatable Seal for use with 21 5 to 23...

Страница 7: ...umatic SST static AE AE AE SST Ram piston rods 6 6 6 Exposed pneumatic carbon steel inflatable 7 7 7 Exposed pneumatic carbon steel static Not ATEX Not intended for use in explosive or hazardous envir...

Страница 8: ...le the ram position control switch BC up and down to bleed air from the ram cylinders The ram will slowly move to the bottom of its travel 3 For electro pneumatic control a Stop evacuation activity b...

Страница 9: ...Cylinder Cylinder Cap Cap Cap 1 Perform the Pump Pressure Relief procedure 2 Perform the Ram Pressure Relief procedure and turn off facility air to the system 3 Disconnect the air cylinder air lines...

Страница 10: ...p assembly a Install inner o ring 7 and outer o ring 8 on the cap 3 b Install o ring 6 in bushing 4 c From the side of the cap with the bolt flange insert bushing into cap d From the smaller diameter...

Страница 11: ...nual for more information Air leaks around cylinder rod Worn rod seal Replace Ram air pressure is too high Decrease Seal not fully inflated Increase seal air pressure check for seal air leak Use the f...

Страница 12: ...ect fluid line Turn on air If pump starts the fluid line is clogged Worn throat packing Replace throat packing Pump operates but output low on both strokes Damaged cylinder seal Replace seal Pump inle...

Страница 13: ...Parts Parts Parts Parts 3A5404F 13...

Страница 14: ...Parts 14 3A5404F...

Страница 15: ...Parts 3A5404F 15...

Страница 16: ...Parts 16 3A5404F...

Страница 17: ...Parts 3A5404F 17...

Страница 18: ...2 3 17V700 25D947 CAP 2 4 17V713 25E543 BUSHING ram top 2 5 17R789 25E543 RETAINER spiral 2 6 17R802 25E543 O RING 322 2 7 120998 25E543 O RING 2 8 514316 25E543 O RING 4 9 17R791 25E543 RETAINER 4 10...

Страница 19: ...C31 6 1 3 1 approval per EN10204 2004 25N008 12 1 2 1 approval per EN10204 2004 25N008C31 12 1 3 1 approval per EN10204 2004 101 PUMP double ball 25N010 5 1 2 1 approval per EN10204 2004 25N010C31 5 1...

Страница 20: ...all pump 0 17W711 5 1 double ball pump 1 17W712 12 1 priming piston pump 1 17W713 6 1 priming piston pump 1 111 17W714 SETSCREW only used if Ref 110 is used 1 112 16F384 FITTING 1 2 npt x 1 2 PTC 1 11...

Страница 21: ...oroprene 25P318 inflatable EPDM WIPER 608193 Buna N wiper seal for 21 5 in diameter drum 202 18A057 Buna N wiper seal for 22 5 in diameter drum 1 203 16D169 GASKET 2 204 118598 CLAMP sanitary 2 205 16...

Страница 22: ...6 x 1 in 4 311 CONTROL air refer to separate air controller manual 1 25E038 25E030 Manual pneumatic exposed static seal 25D266 25E650 Manual pneumatic exposed inflatable seal 25C543 25P255 Enclosed ma...

Страница 23: ...cessory code code code AC AC AC Kit Kit Kit Part Part Part Number Number Number 25E153 25E153 25E153 Painted carbon steel dolly for drums up to 24 inch diameter Load rating of 2000 pounds Kit contains...

Страница 24: ...279 Kg Electro Electro Electro pneumatic pneumatic pneumatic Control Control Control Panel Panel Panel Enclosure Type 4X IP65 Voltage 100 240 VAC Phase 1 Frequency 50 60 Hz Maximum Current 1 3 A NOTE...

Страница 25: ...Notes Notes Notes Notes 3A5404F 25...

Страница 26: ...ARRANTY WARRANTY WARRANTY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AN...

Отзывы: