Follow the Pressure Relief Procedure
whenever you see this symbol.
WARNING
WARNING
WARNING
This equipment stays pressurized until pressure
is manually relieved. To help prevent serious
injury from pressurized fluid, such as skin
injection, splashing fluid and moving parts, follow
the Pressure Relief Procedure when you stop
dispensing and before cleaning, checking, or
servicing the equipment.
1.
Follow the Pressure Relief Procedure in the
system operation manual where this control
panel is installed to place the system in a
safe maintenance position before servicing the
equipment.
2.
Turn off all air supply valves located on the
bottom of the control panel.
Software
Software
Software Updates
Updates
Updates
Contact Graco technical assistance to receive
software updates. Software will be sent via email.
WARNING
WARNING
WARNING
ELECTRIC
ELECTRIC
ELECTRIC SHOCK
SHOCK
SHOCK HAZARD
HAZARD
HAZARD
To prevent injury, such as electric shock, turn
off power at main switch before servicing the
equipment.
NOTICE
NOTICE
NOTICE
If power is lost during the update, indeterminate
results will occur and the system may not be able
to operate when power is restored.
1.
Prior to loading update, record recipes and
settings. This must be done manually.
2.
On a computer, unzip the software zip file. Do
not change the names on any of the unzipped
files or directories. Copy all files and directories
in the unzipped file onto the root level of a USB
flash drive.
3.
Lower the ram to its lowest position.
4.
Power off the unit and disconnect all power to
the control panel.
5.
Inside the control panel, install the USB flash
drive into the USB port on the bottom of the
display unit.
6.
Close the panel door.
7.
Apply power to the control panel and observe
the display screen. Various information will be
displayed during the software update. When the
automatic run screen is displayed, the update
has successfully completed.
NOTE:
NOTE:
NOTE: If the automatic screen is not displayed
within 10 minutes, the update may have failed.
Cycle power to the control panel to restart the
update again.
8.
Power off the unit and disconnect all power to the
control panel. Remove the USB flash drive and
close the control panel.
9.
Verify that settings and recipes have been
retained. If they were not retained, enter the
recorded settings and recipes.