Technical Data
Technical Data
SaniForce Electric Double Diaphragm Pump
US
Metric
Maximum fluid working pressure
2150
100 psi
0.69 MPa, 6.9 bar
3000HS, 4000HS
60 psi
0.41 MPa, 4.1 bar
Air pressure operating range
2150
20 to 100 psi
0.14 to 0.69 MPa, 1.4
to 6.9 bar
3000HS, 4000HS
20 to 60 psi
0.14 to 0.41 MPa, 1.4
to 4.1 bar
Air inlet size
3/8 in. npt(f)
Maximum suction lift (reduced if checks don’t seat well due to damage, blockage, or extreme speed of cycling)
2150 (@ 20 Hz)
Wet: 30 ft
Dry: 14 ft
Wet: 9.1 m
Dry: 4.3 m
3000HS, 4000HS
Wet: 30 ft
Dry: 8.4 ft
Wet: 9.1 m
Dry: 2.5 m
Maximum size pumpable solids
2150T, 2 in. balls
1/4 in.
6.3 mm
3000HS, 3 in. flapper
2.6 in.
66.0 mm
4000HS, 4 in. flapper
3.8 in
96.5 mm
Minimum ambient air temperature for operation and
storage.
NOTE: Exposure to extreme low temperatures may result
in damage to plastic parts.
32° F
0° C
Fluid displacement per cycle (free-flow)
2150T
0.6 gallons
2.27 liters
3000HS, 4000HS
0.69 gallons
2.61 liters
Maximum free-flow delivery (continuous duty)
2150T
100 gpm
378 lpm
3000HS, 4000HS
62.5 gpm
237 lpm
Maximum pump speed (continuous duty)
60 Hz/160 cpm
Fluid Inlet and Outlet Size
2150T, Stainless Steel
2.5 in sanitary connection or 65 mm DIN 11851
2150HS
2 in. sanitary connection
3000HS, 3A, PH, Stainless Steel
3 in. sanitary connection
4000HS, 3A, PH, Stainless Steel
4 in. sanitary connection
Electric Motor
AC, Standard CE (
04A, 05A, 06A
)
Power
7.5 HP
5.5 kW
Number of Motor Poles
4–Pole
Speed
1800 rpm (60 Hz) or 1500 rpm (50 Hz)
Constant Torque
6:1
Gear Ratio
11.25
Voltage
3–phase 230V / 3–Phase 460V
3A5132F
33