Troubleshooting
12
312408F
Primary Heaters (A and B)
Before performing any troubleshooting procedures:
1.
Relieve pressure, page 15.
2.
Turn main power OFF
.
3.
Allow equipment to cool.
Try the recommended solutions in the order given for
each problem, to avoid unnecessary repairs. Also,
determine that all circuit breakers, switches, and con-
trols are properly set and wiring is correct before assum-
ing there is a problem.
PROBLEM
CAUSE
SOLUTION
Primary heater(s) does not heat.
Heat turned off.
Press
or
zone
keys.
Temperature control alarm.
Check temperature display for diag-
nostic code, page 7.
Signal failure from thermocouple.
See E04: Fluid Temperature Sen-
sor (FTS) or thermocouple discon-
nected, page 9.
Control of primary heat is abnormal;
high temperature overshoots or E01
error occurs intermittently.
Dirty thermocouple connections.
Examine connection of thermocou-
ples to long green plug on heater
control board. Unplug and re-plug
thermocouple wires, cleaning off any
debris. Unplug and re-plug long
green connector.
Thermocouple not contacting heater
element.
Loosen ferrule nut (N), push in ther-
mocouple (310) so tip (T) contacts
heater element (307). Holding themo-
couple tip (T) against heater element,
tighten ferrule nut (N) 1/4 turn past
tight. See page 22 for illustration.
Failed heater element.
See Primary Heaters, page 21.
Signal failure from thermocouple.
See E04: Fluid Temperature Sen-
sor (FTS) or thermocouple discon-
nected, page 9.
Thermocouple wired incorrectly.
See E04: Fluid Temperature Sen-
sor (FTS) or thermocouple discon-
nected, page 9. Power up zones one
at a time and verify that temperature
for each zone rises.
A
B
Содержание Reactor HT Series
Страница 43: ...Parts 312408F 43 ...