Error
Location
Type
Description
Cause
Solution
Tripped circuit
breaker.
Visually check circuit
breaker for a tripped
condition.
A8DA
Heater A
No Current A
Loose/broken
connection.
Check heater wiring for
loose wires.
Tripped circuit
breaker.
Visually check circuit
breaker for a tripped
condition.
A8DB
Heater B
No Current B
Loose/broken
connection.
Check heater wiring for
loose wires.
Tripped circuit
breaker.
Visually check circuit
breaker for a tripped
condition.
A8DH
Hose
No Current Hose
Loose/broken
connection.
Check heater wiring for
loose wires.
334946A