Technical Specifications
Reactor 2 E-30 and E-XP2 Proportioning System
U.S.
Metric
Maximum Fluid Working Pressure
E-30
2000 psi
14 MPa, 140 bar
E-XP2
3500 psi
24.1 MPa, 241 bar
Maximum Fluid Temperature
E-30
190°F
88°C
E-XP2
190°F
88°C
Maximum Flow Rate
E-30
30 lb/min
13.5 kg/min
E-XP2
2 gpm
7.6 lpm
Maximum Heated Hose Length
Length
310 ft
94 m
Output per Cycle
ISO and RES
E-30
0.0272 gal.
0.1034 liter
E-XP2
0.0203 gal.
0.0771 liter
Operating Ambient Temperature Range
Temperature
20° to 120°F
-7° to 49°C
Heater Power
E-30 10 kw
10,200 Watts
E-30, 15 kw
15,300 Watts
E-XP2 15 kw
15,300 Watts
Sound Pressure
Sound Pressure measured per ISO-9614–2.
E-30
Measured from 3.1 ft (1 m), at
1000 psi (7 MPa, 70 bar), 3 gpm
(11.4 lpm)
87.3 dBA
E-XP2
Measured from 3.1 ft (1 m), at
3000 psi (21 MPa, 207 bar), 1 gpm
(3.8 lpm)
79.6 dBA
333024A
95
Содержание Reactor 2 E-30
Страница 69: ...Parts Parts Proportioners 333024A 69...
Страница 82: ...Parts Electrical Enclosure 82 333024A...
Страница 90: ...Electrical Schematics Available Circuit Breakers Part Amps 126128 20 126131 40 24L960 50 90 333024A...
Страница 91: ...Electrical Schematics 1 16U529 16V515 15D906 24U855 1 Locate near TCM 333024A 91...