Repair
3A3101F
29
air piston cylinder is brought closer to the air motor
housing. Light pressure is required to keep the air
piston cylinder in place. Ensure the cylinder (8) is
pushed down to the hard stop so that the set screws
(10) engage the groove.
6.
Reinstall and tighten the three set screws (10) to
hold the air piston cylinder (8) in place.
7.
Tighten the packing nut (16) to a torque of 15 in-lbs
(1.7 N•m), then loosen and tighten again it to a final
torque of 5 in-lbs (0.6 N•m).
NOTE:
If a torque wrench is not present in the field, an
alternative method is to tighten the nut finger tight
through the window, then use a small punch or hex
wrench to further tighten by approximately 10 degrees.
NOTE:
If the packing nut (16) is over-tightened, the
pump may not complete a full stroke and seal life will be
compromised.
Check Valves
Inlet Check Valve Repair (all models except
PCI-xxx-xxH)
1.
2.
Remove the inlet check valve assembly (17).
3.
Remove the retaining nut (17a) and piston (17b).
4.
Remove the piston o-ring (17c).
5.
Inspect parts for wear, replace as needed.
6.
Install the piston o-ring (17c), piston (17b), and
retaining nut (17a).
7.
Reconnect the inlet check valve assembly (17).
F
IG
. 16 Tighten packing nut
16
F
IG
. 17 Inlet check valve assembly
17a
17b
17c
17