Calibration Steps
1. Press
to enter Setup Mode.
2. Press
to move to Setup Screen 5.
3. Press
to enter the screen.
4. Press
to begin the calibration.
5. Dispense about 300–500 cc of material into a
graduated cylinder. The amount the system
measures will display in the measured volume
field
.
6. Press
to end the calibration.
7. Press
to get to the dispensed volume field
, then press
to enter the field. Enter
the amount of material in the cylinder.
8. After the volume is entered, the system calculates
the new k-factor and shows it on Setup Screen 5.
NOTE: To clear the counter and begin the
calibration again, press
, move briefly to
another screen, then return to Setup Screen 4
and start over. If you press
without leaving
the screen, the counter will continue from where
it is, without clearing.
9. Press
to exit the screen.
10. Press
to exit Setup Mode.
Set the Modbus Addresses
See Setup Screen 7. By default, the Modbus is
set to Off
. If you need the Modbus, set the
Modbus mode to SLAVE
. The address
value is between 1 and 247. The modbus address
corresponds to the address of the ProControl 1KE.
See Appendix A for further information.
Set the Flow Rate Percent
1. System Setup: See
to
set the upper and lower limit within which the
operator can adjust the flow rate. The settable
range is 0 to 99.9 percent, but the I/P pressure
transducer requires a minimum of 22 to 25 flow
rate percent target to start flow. Therefore, the
operational range is about 22 to 99.9 percent.
See Table 1.
Table 3
Flow Rate
Target
I/P Current
Effect
0–about 20
percent
0–4.0 mA
No flow
22%-25%
4.4–5.0 mA
Lowest flow
rate
55% — 60%
11–12 mA
Middle flow
rate
99.9%
20 mA
Highest flow
rate
2. Operator: See
to adjust
the flow rate within the set limits.
Update the Software
Software updates are installed using a software token
(PN 16P892), which is sent automatically when a new
version of the software is released. Manual 3A1244
will accompany any necessary software updates.
Follow all instructions and warnings in Manual
3A1244 to update your ProControl 1KE software.
3A2614H
19
Содержание ProControl 1KE
Страница 16: ...Installation Typical Installation Non Hazardous Location Hazardous Location 16 3A2614H ...
Страница 34: ...Parts Parts Kits for Hazardous Location 24L085 24P593 24P595 24L087 24P597 24L089 24L091 34 3A2614H ...
Страница 36: ...Parts Kits for Non Hazardous Location 24L084 24L086 24L088 24L090 24P592 24P594 24P596 36 3A2614H ...
Страница 38: ...Parts Fluid and Air Control Parts 38 3A2614H ...
Страница 52: ...Notes Notes 52 3A2614H ...