16 309244
Troubleshooting
PROBLEM
CAUSE
SOLUTION
No fluid delivery
No material, no remote container
pressurization, hose or pickup tube
clogged
Check container for material.
Check for leaks at the container gasket
(2-quart pressure pot cover or
2
1
/
2
-gallon pressure pot wing nuts).
Tighten wing nuts if loose.
Check for air flow from male quick
disconnect at compressor outlet
(approx. 1/4 CFM – 233452; 1/2 CFM –
233449).
Turn pressure regulator clockwise.
Look for pressure on gauge. (If no
pressure on gauge, check air line and
fittings).
Check hole in 2
1
/
2
-gallon pot cover
under regulator or in 2-quart pot cover
at needle valve.
Clean if necessary.
Check for obstructions or kinks in
hoses and fittings.
Check if fluid pickup tube is unplugged.
Tighten.
Blow out and clear material hose.