Fluid
Fluid
Fluid Packing
Packing
Packing Rod
Rod
Rod Removal
Removal
Removal
1.
Follow the steps in
Prepare the Gun for Service, page 48
2.
Remove the air cap and fluid nozzle. See
Air Cap and Nozzle Replacement, page 49
.
3.
Remove the electrode.
See
Electrode Replacement, page 52
4.
Loosen the trigger screws (13) and remove the
trigger (12).
5.
Remove the packing rod (2), using the multi-tool
(41). Remove the spring (17).
6.
Check all parts for wear or damage and replace
if necessary.
Figure 27 Fluid Packing Rod Removal
Packing
Packing
Packing Rod
Rod
Rod Repair
Repair
Repair
Replace the packing rod as individual parts or as an
assembly.
Adjust
Adjust
Adjust the
the
the Air
Air
Air Flow
Flow
Flow Lead
Lead
Lead and
and
and Lag
Lag
Lag
The gun begins emitting air before the fluid is
discharged and the fluid stops before the air flow
stops. The packing rod assembly is pre-adjusted at
the factory for proper air lead and lag. Adjust only
if necessary, as follows.
1.
Remove the spring (17) from the nut (2k).
2.
Use a hex wrench to hold the end of the packing
rod. Turn both adjustment nuts (2j, 2k) out to
increase the lead/lag time for the air flow. The
recommended adjustment is one half turn and
not more than one full turn.
3.
Tighten the nuts together to fix them in the new
position.
3A7504A