Electrode
Electrode
Electrode Replacement
Replacement
Replacement
1.
Follow the steps in
Prepare the Gun for Service, page 48
2.
Remove the air cap and nozzle. See
Air Cap and Nozzle Replacement, page 49
.
3.
Unscrew the electrode (3) with the multi-tool (41).
NOTICE
NOTICE
NOTICE
To avoid damaging the plastic threads, be very
careful when installing the electrode.
4.
Apply low-strength purple threadlocker to the
electrode and packing rod threads. Install the
electrode finger-tight. Do not overtighten.
5.
Install the fluid nozzle and air cap. See
Air Cap and Nozzle Replacement, page 49
.
NOTICE
NOTICE
NOTICE
To avoid equipment damage, use only the
electrode needle available in kit 26A416.
Alternate electrodes are not acceptable for use
and do not fit the packing rod threads.
Figure 25 Electrode Replacement
Needle
Needle
Needle Replacement
Replacement
Replacement (Model
(Model
(Model L60M19)
L60M19)
L60M19)
1.
See
Prepare the Gun for Service, page 48
.
2.
Remove the air cap and nozzle. See
Air Cap, Spray Tip, and Nozzle Replacement
(Model L60M19), page 50
3.
Unscrew the needle (3).
4.
Apply low-strength (purple) Loctite® or equivalent
thread sealant to the needle and packing rod
threads. Install the needle finger-tight. Do not
overtighten.
5.
Install the fluid nozzle and air cap. See
Air Cap, Spray Tip, and Nozzle Replacement
(Model L60M19), page 50
6.
See
.
Figure 26 Electrode Replacement
52
3A7504A
Содержание Pro Xp 60 WB