Turn the air motor upside down and place the fluid
pump on the mounting tubes (P, Q). Leaving the
coupling nut (22) loose, move the pump to align
with the rods. Install and tighten the larger locknut
(45) and lock in place with the setscrew (40).
Being careful not to disturb the alignment, install
and tighten the other locknut (44). Tighten the
coupling nut securely. See Fig. 6.
9.
If the grounding wire was disconnected before
servicing, be sure to reconnect it before operating
the pump.
10. Operate pump at a minimum air pressure (50 psi,
0.35 MPa, or 3.5 bar). Adjust small mounting tube
(Q) locknuts (44) as necessary until pump runs
smoothly at 15 psi (0.1 MPa, 1.05 bar).