Recycling and Disposal
3A8824A
11
Final Lubrication Setup
With all components installed and the system
completely primed, the system is ready to run.
The Mongoose Chemical Pump (AA) suggested rate is
10 cycles, 100% of stroke. The pump may run
continually.
For the IGS fluid (107) level in the collecting bottle (104):
• The IGS fluid must continually recirculate.
• The IGS fluid level in the bottle must allow the
filter/suction to float inside of the bottle.
• The return valve exit port must be above the IGS
fluid level to avoid flooding the return valve exit
port. If there is thickening of the returning drop or
cloudy/discolored media in the collecting bottle
(104), change the recirculation IsoGuard Select
(IGS) material (107).
The system can run independent of the PR70 and can
run 24/7 regardless of whether the metering system is
being used.
NOTE:
IsoGuard Select (IGS) is for PUR or reactive
polyurethane materials. IGS is designed to dissolve and
suspend the polyurethane materials. IGS will thicken or
solidify after a period of time and should be replaced
once the material starts to thicken.
Recycling and Disposal
End of Product Life
At the end of a product’s useful life, recycle it in a
responsible manner.