background image

Warnings

311833F

5

PRESSURIZED EQUIPMENT HAZARD

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and 
cause serious injury.

Follow 

Pressure Relief Procedure

 in this manual, when you stop spraying and before cleaning, 

checking, or servicing equipment. 

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

MOVING PARTS HAZARD

Moving parts can pinch or amputate fingers and other body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards or covers removed.

Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, 
follow the 

Pressure Relief Procedure

 in this manual. Disconnect power or air supply.

SKIN INJECTION HAZARD 

High-pressure fluid from dispense valve, hose leaks, or ruptured components will pierce skin. This may 
look like just a cut, but it is a serious injury that can result in amputation. 

Get immediate surgical 

treatment.

Do not point dispense valve at anyone or at any part of the body.

Do not put your hand over the end of the dispense nozzle.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Follow 

Pressure Relief Procedure

 in this manual, when you stop spraying and before cleaning, 

checking, or servicing equipment. 

WARNING

Содержание P06DCK

Страница 1: ...SG P06MSG 620 psi 4 2 MPa 42 7 bar Maximum Working Pressure 100 psi 0 69 MPa 6 9 bar Maximum Air Inlet Pressure Models P10DCK P10ECK P10LCK P10MCK P10LCS 1180 psi 8 14 MPa 81 4 bar Maximum Working Pre...

Страница 2: ...Procedure 8 Maintenance 9 Shutdown 9 Care of the Pump 9 Flushing 9 Lubrication 9 Troubleshooting 11 Repair 12 Required Tools 12 Disconnect the Lower 12 Reconnect the Lower 13 Models P06DCK P06ECK P06...

Страница 3: ...otor with DataTrak M stainless steel construction S PTFE PTFE packing configuration G To order replacement parts see Parts List section starting on page 15 The digits in the matrix do not correspond t...

Страница 4: ...reas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Comply with all applicable safety regulations...

Страница 5: ...t with protective guards or covers removed Pressurized equipment can start without warning Before checking moving or servicing equipment follow the Pressure Relief Procedure in this manual Disconnect...

Страница 6: ...or cardboard which interrupts grounding continuity To maintain grounding continuity when flushing or relieving pressure hold metal part of the spray gun firmly to the side of a grounded metal pail the...

Страница 7: ...fluid pressure Gun or valve to dispense fluid Fluid line swivel for easier gun movement Suction kit enables the pump to draw fluid from a container Flush Before Using Equipment The equipment was teste...

Страница 8: ...gage the trigger lock 6 Open all fluid drain valves in the system having a waste container ready to catch drainage Leave drain valve s open until you are ready to spray again 7 If you suspect the spra...

Страница 9: ...ay tip before flushing Start the pump Hold a metal part of the gun firmly to the side of a grounded metal pail and use the lowest possible fluid pressure during flush ing When flushing is complete rel...

Страница 10: ...Maintenance 10 311833F...

Страница 11: ...ves PROBLEM CAUSE SOLUTION Pump does not operate or no fluid flow Loose or broken pump parts Disassemble check repair Restricted line or inadequate air supply Clear increase Exhausted fluid supply Ref...

Страница 12: ...he coupling nut 3 from the connecting rod adapter 5 Remove the coupling collars do not lose or drop them See FIG 3 5 Hold the tie rod flats with a wrench to keep the rods 6 from turning Unscrew the nu...

Страница 13: ...he Lower Place the lower 2 on the tie rods 6 5 Screw the nuts 7 onto the tie rods 6 and torque as noted in FIG 3 6 Screw the coupling nut 3 onto the connecting rod adapter 5 loosely Hold the connectin...

Страница 14: ...Repair 14 311833F Models P06DSG P06ESG P06LSG P06MSG Models P06DCK P06ECK P06LCK P06MCK P10DCK P10ECK P10LCK P10MCK P10LCS FIG 4 6 7 3 4 5 15 1 ti8334b 2 FIG 5 ti8335b 6 7 3 4 5 15 1 2...

Страница 15: ...1 MOTOR 3400 low noise datatrak see manual 311238 N34LT0 1 2 PUMP see manual 311717 253597 253597 253597 253597 1 3 NUT coupling 184096 184096 184096 184096 1 4 COLLAR coupling 184130 184130 184130 18...

Страница 16: ...6 311833F Dimensions B A ti8377b Pump Model A in mm B in mm Approx Weight lb kg P06_SG 41 6 1055 28 0 711 113 51 P06_CK 41 6 1055 28 0 711 113 51 P10_CK 41 6 1055 28 0 711 132 62 P10_CS 41 6 1055 28 0...

Страница 17: ...ing Hole Diagram NXT Model 3400 NXT Model 6500 TI8069A TI8070A 6 180 in 157 mm Three 5 8 11 Tie Rod Holes Six 5 8 11 Tie Rod Holes 6 180 in 157 mm 6 186 in 157 mm 6 186 in 157 mm Four 3 8 16 Mounting...

Страница 18: ...e gpm lpm All P06 _ _ _ Models 620 4 2 42 100 0 69 6 9 See Performance Chart 17 4 65 8 All P10 _ _ _ Models 1180 8 14 81 4 100 0 69 6 9 17 4 65 8 A 0 7 MPa 7 bar 100 psi air pressure or 10 5 MPa 105 b...

Страница 19: ...arbon Steel 1000cc Pump with NXT Model 6500 Air Motor Fluid Pressure A B psi MPa bar 700 4 8 48 600 4 1 41 500 3 4 34 400 2 7 27 300 2 0 20 200 1 3 13 100 6 8 68 0 Fluid Flow in gpm lpm C A B C Air Fl...

Страница 20: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANT...

Отзывы: