background image

Installation

Installing the Kit (continued)

2.

Install the restrictor (6), flat side up, into the activa-
tor outlet housing (8).

3.

Place the o-ring (9) in the groove in the activator
outlet housing (8). Lightly lubricate the o-ring.

4.

Secure the activator valve (G) to the plate (7) with
the two screws (E).

5.

Place the o-ring (9) in the groove on the plate (7).
Lightly lubricate the o-ring, and slide the plate, with
the activator valve assembly, onto the top of the
gun body.

6.

Install the gun and activator triggers (A, B) with the
pivot pin (S) and screw (R).

7.

Install the needle (5) into the gun body, then install
the fluid adjustment knob (L) and spring (X).

8.

Pull back the trigger (A) until the activator valve
starts to open. Tighten the two hex nuts on the
activator needle so that both fluid valves open
together.

9.

Install the adjustment nut (4) and the retaining ring
(J) on the air valve (N). Install the air valve assem-
bly into the gun body.

10. Connect the tube (2).

11. Install the air cap (10), and secure it with the

retaining ring (W).

Fig. 3

F

11

E

G

B

A

2

7

8

1

9

6

R

S

05880

9

3

W

10

J

4

N

5

X

L

Lightly lubricate.

Lightly lubricate contact area on trigger (B) face.

Tighten to 25–35 in-lbs (2.8–4.0 N

S

m).

Tighten to 1–5 in-lbs (0.1–0.6 N

S

m).

Tighten to 10–15 in-lbs (1.1–1.7 N

S

m).

Tighten to 20 in-lbs (2.3 N

S

m).

Tighten to 5 in-lbs (0.6 N

S

m).

Отзывы: