background image

Installation

312795K

11

Grounding

Pump: See F

IG

. 4. Verify that the ground screw (GS) is 

attached and tightened securely to the air motor. Con-
nect the other end of the ground wire (S) to a true earth 
ground.

Air and fluid hoses: Static electricity may build up 
when fluids flow through pumps, hoses, and sprayers. 
At least one hose must be electrically conductive, with a 
maximum of 500 ft. (150 m) combined hose length to 
ensure grounding continuity. Check electrical resistance 
of hose. If total resistance to ground exceeds 25 meg-
ohms, replace hose immediately.

Air compressor: follow manufacturer’s recommenda-
tions.

Spray gun / Dispense valve:

 

Ground the spray gun 

through connection to a Graco-approved grounded fluid 
hose.

Fluid supply container: follow local code.

Object being sprayed: follow local code.

Solvent pails used when flushing: follow local code. 
Use only conductive metal pails, placed on a grounded 
surface. Do not place the pail on a nonconductive sur-
face, such as paper or cardboard, which interrupts 
grounding continuity.

To maintain grounding continuity when flushing or 
relieving pressure: 
hold metal part of the spray 
gun/dispense valve firmly to the side of a grounded 
metal pail, then trigger the gun/valve.

Mount the Pump

Mount the pump directly to the wall (order Wall Mounting 
Kit, page 22) or to a Graco cart (order Cart Mounting Kit 
24E879). Pump dimensions are shown on page 27.

Wall-Mounted Pumps

1.

Be sure the wall can support the weight of the 
pump, bracket, hoses and accessories, as well as 
the stress caused during operation.

2.

Position the wall bracket about 1.2-1.5 m (4-5 ft) 
above the floor. For ease of operation and service, 
make sure the pump air inlet, fluid inlet, and fluid 
outlet ports are easily accessible.

3.

Using the wall bracket as a template, drill 10 mm 
(0.4 in.) mounting holes in the wall. Wall mounting 
dimensions are shown on page 28.

4.

Attach the bracket to the wall. Use 9 mm (3/8 in.) 
screws that are long enough to keep the pump from 
vibrating during operation.

NOTE: Be sure the pump is level.

Cart-Mounted Pumps

Kit 24E885 is available if you plan to bolt your cart to the 
floor. It includes two spacers that keep the legs stable. 
Bolts not included.

Air and Fluid Hoses

Be sure all air hoses (N) and fluid hoses (M) are prop-
erly sized and pressure rated for your system. See F

IG

3. Use only electrically conductive fluid hoses.

The equipment must be grounded. Grounding 
reduces the risk of static and electric shock by pro-
viding an escape wire for the electrical current due to 
static build up or in the event of a short circuit.

F

IG

. 4. Ground the Pump.

S

GS

ti12914a

Содержание Merkur A Series

Страница 1: ...s UV coatings and other moisture sensitive materials For professional use only See page 7 for model information including maximum working pressure Important Safety Instructions Read all warnings and i...

Страница 2: ...r Lock 14 Prime and Adjust the Pump 15 Shutdown and Care of the Pump 15 Maintenance 16 Preventive Maintenance Schedule 16 Tighten Threaded Connections 16 Flushing 16 Troubleshooting 17 Repair 18 Gener...

Страница 3: ...ed hoses Hold gun firmly to side of grounded pail when triggering into pail If there is static sparking or you feel a shock stop operation immediately Do not use equipment until you identify and corre...

Страница 4: ...plicable safety regulations MOVING PARTS HAZARD Moving parts can pinch cut or amputate fingers and other body parts Keep clear of moving parts Do not operate equipment with protective guards or covers...

Страница 5: ...arts with ISO pump oil or grease when reassembling Changing Materials When changing materials flush the equipment mul tiple times to ensure it is thoroughly clean Always clean the fluid inlet strainer...

Страница 6: ...tion starting on page 20 The digits in the matrix do not correspond to the reference numbers in the Parts drawings and lists Cycle refers to combination of one upstroke and one downstroke ID ti12922a...

Страница 7: ...0B B15BB1 Series A M04LT0 B15FA0 Series A M12LN0 LB150A 1500 10 3 103 2 4 9 0 1 in npt 3 4 in npt 1 2 in npt B15FB0 Series A M12LT0 B15FA1 Series A M12LN0 LB150B B15FB1 Series A M12LTO B23DA0 Series A...

Страница 8: ...tor B Coupler Shield C Connecting Rod D Tie Rod E Fluid Inlet F Bellows Chamber G Fluid Outlet H Ground Wire J Coupling Nut K Coupling Collar L Packing Nut M Pump Adapter N Jam Nut P Cylinder R Foot C...

Страница 9: ...uides for selecting and installing system components and accessories Contact your Graco distributor for assistance in designing a sys tem to suit your particular needs Prepare the Operator All persons...

Страница 10: ...Have a grounded metal pail available for use when flushing the system Key A Air Shutoff Valve B Air Filter optional accessory C Gun Air Pressure Gauge D Gun Air Pressure Regulator E Bleed Type Master...

Страница 11: ...rigger the gun valve Mount the Pump Mount the pump directly to the wall order Wall Mounting Kit page 22 or to a Graco cart order Cart Mounting Kit 24E879 Pump dimensions are shown on page 27 Wall Moun...

Страница 12: ...air supply Air shutoff valve A isolates air line accessories for servicing Locate upstream from all other air line accessories Gun air regulator D controls air pressure to the air assisted spray gun F...

Страница 13: ...logged Very slowly loosen the hose end coupling at the gun and relieve pressure gradually Then loosen completely to clear the obstruction c After following the steps above if the spray tip or hose sti...

Страница 14: ...r to control the pump speed and the fluid pressure Always use the lowest air pres sure necessary to get the desired results Higher pressures cause premature tip nozzle and pump wear Shutdown and Care...

Страница 15: ...f the day Before storing the pump Flush at the lowest pressure possible Flush with a fluid that is compatible with the fluid you are pumping and with the wetted parts in your system Check with your fl...

Страница 16: ...cement Pump manual No output Improperly installed ball check valves Check and repair See Bellows Displace ment Pump manual Pump operates erratically Exhausted fluid supply Refill and reprime pump Held...

Страница 17: ...low these instructions to remove the entire pump from the wall or cart bracket For wall mounted packages you may prefer to remove the entire pump even if only the air motor requires repair 1 Follow al...

Страница 18: ...ch to turn the motor shaft To avoid damage to the bellows top cap and the D shaped seal do not turn the coupling nut See FIG 7 4 Lower the coupling nut 7 and remove the coupling collars 5 See FIG 8 5...

Страница 19: ...the Displacement Pump 1 Align the straight edge of the pump adapter with the back of the air motor Slide the pump adapter onto the tie rods 3 2 Attach the tie rod nuts 4 and torque to 50 60 ft lb 68...

Страница 20: ...Parts 20 312795K Parts Torque to 50 55 ft lb 1 1 2 3 4 7 5 8 Torque to 50 60 ft lb 2 Torque to 75 80 ft lb 3 3 2 1 10 2 ti15367a 9 6 4 M04xxx air motors only counterbore end faces 4...

Страница 21: ...24E992 LIFT RING with o ring 1 11 290079 TAG warning grounding not shown 1 12 15W718 LABEL warning not shown 1 13 15W719 LABEL warning not shown 1 Model Displacement Pump 1 Motor 2 Motor Piston Diam...

Страница 22: ...LB150A and LB150B 3 5 in motor 4 5 in motor 4 5 in motor 6 0 in motor 7 5 in motor 3 5 in motor 6 0 in motor 7 5 in motor Coupling Collars 5 Package of 10 24A619 24A619 24A619 Connecting Kit Includes...

Страница 23: ...100 0 7 7 200 1 4 14 300 2 1 21 400 2 8 28 500 3 5 35 0 5 1 9 1 0 3 8 1 5 5 7 2 5 9 5 2 0 7 6 A B C A B C 14 0 4 12 0 34 10 0 28 8 0 23 6 0 17 4 0 11 2 0 06 Model B12Dxx 12 1 Ratio 100cc cycle Fluid...

Страница 24: ...m tested in No 10 weight oil Fluid Outlet Pressure psi MPa bar Air Flow scfm m 3 min 0 0 Model B15Fxx 15 1 Ratio 150cc cycle 400 2 8 28 800 5 5 55 1200 8 3 83 1600 11 0 110 0 5 1 9 1 0 3 8 1 5 5 7 2 5...

Страница 25: ...t oil Fluid Outlet Pressure psi MPa bar Air Flow scfm m 3 min 0 0 A B C A B C Model B23Dxx 23 1 Ratio 100 cc cycle 500 3 4 34 1000 6 9 69 1500 10 3 103 2000 13 8 138 2500 17 2 172 0 2 0 8 0 6 2 3 1 0...

Страница 26: ...ted in No 10 weight oil Fluid Outlet Pressure psi MPa bar Air Flow scfm m 3 min Model B35Dxx 35 1 Ratio 100 cc cycle 1000 6 9 69 2000 13 8 138 3000 20 7 207 4000 27 6 276 0 2 0 8 0 6 2 3 1 0 3 8 1 4 5...

Страница 27: ...B15BAx 33 838 6 9 175 5 8 147 9 7 246 35 888 48 21 B15BBx 49 22 B15FAx 33 5 851 8 6 218 11 7 297 11 4 290 35 6 904 74 33 B15FBx 75 34 B23DAx 33 5 851 8 6 218 11 7 297 11 4 290 35 6 904 70 31 B23DBx 71...

Страница 28: ...inlet pressure 15 psi 0 1 MPa 1 0 bar Maximum air inlet pressure 100 psi 0 7 MPa 7 bar Minimum air inlet pressure 10 psi 0 07 MPa 0 7 bar Air consumption See Performance ChartsPerformance Charts page...

Страница 29: ...California Proposition 65 312795K 29 California Proposition 65 CALIFORNIA RESIDENTS WARNING Cancer and reproductive harm www P65warnings ca gov...

Страница 30: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANT...